S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
COSFULLI  
The Change of State FIFO Full Interrupt bit (COSFULLI) indicates that the Change of State  
FIFO is full. When logic 1, the COSFULLI indicates that the Change of State FIFO is full,  
and no more change of state notifications can be written into the FIFO. This suspends a  
background process until FIFO space becomes free. It is the responsibility of the  
management software to ensure this FIFO is read often enough to ensure the notification of  
changes of state are compliant with Bellcore and ITU standards. This bit is cleared when this  
register is read.  
XCOSI  
The Excessive Change of State FIFO Interrupt bit (XCOSI) indicates that the Change of  
State FIFO is half-full. When logic 1, the XCOSI indicates that the Change of State FIFO is  
half-full with changes of connection state information. This indicates that the Change of  
State FIFO should be read quickly to avoid the Change of State FIFO from becoming full. It  
is the responsibility of the management software to ensure the Change of State FIFO is read  
often enough to ensure the notification of changes of state are compliant with Bellcore and  
ITU standards. This bit is cleared when this register is read.  
COSI  
The Change of State Interrupt bit (COSI) indicates that the Change of State FIFO has become  
non-empty.  
CROFULLI  
The Count Rollover FIFO Full Interrupt bit (CROFULLI) indicates that the Count Rollover  
FIFO is full. When logic 1, the CROFULLI indicates that the Count Rollover FIFO is full,  
and no more rollover notifications can be written into the FIFO. This causes the counts to  
retain their MSBs high until room is made in the Count Rollover FIFO.  
XCROI  
The Excessive Count Rollover FIFO Interrupt bit (XCROI) indicates that the Count  
Rollover FIFO is half-full. This indicates that the Count Rollover FIFO should be read  
quickly to avoid it becoming full.  
CROI  
The Count Rollover FIFO Interrupt bit (CROI) indicates that the Count Rollover FIFO has  
become non-empty.  