Operating Procedures
■ Flow of Operation
Initial Settings
Setting Resolution and
Rotation Direction
The Encoder resolution and rotation direction is set on a DIP switch.
➾ For details on the setting methods, refer to page 21.
The Encoder is mounted to the machine and the origin for operation is determined.
➾ For details on the setting methods, refer to page 21.
Setting the Origin
Parameters can be set in Function Setting Mode to perform more advanced operations.
➾ For details, refer to page 26 Advanced Functions.
Advanced
function
Setting Functions
Programming Cams (Programming Mode)
Setting ON/OFF Angles
There are three methods that can be used to set or change ON/OFF angles (i.e., cam programming).
• Using the ANGLE Keys (Manual Mode)
• Actually turning the Encoder (Teaching Mode)
• Setting from personal computer using Support Software (order separately)
➾ For details on the setting methods, refer to pages 22 to 23.
Advance angle compensation (ADV) function can be set if required.
➾ For details on the setting methods, refer to page 27.
Advanced
function
Setting the ADV Function
The machine is operated and outputs are actually made to check the timing of operation.
If the timing of operation is not correct, it can be changed.
➾ For details, refer to page 23.
Checking Timing (Test Mode)
Operation is started.
Operation (Run Mode)
Checking ON/OFF Angle Settings
Clearing Settings
➾ For details, refer to page 24.
The ON/OFF angles that have been set can be checked.
➾ For details, refer to page 24.
Deletes settings. There are two methods that can be used to delete settings.
• Clearing all programs (deletes all programming)
• Clearing individual steps, cams, and banks
➾ For details, refer to page 25.
■ Settings for Basic Functions
Programming Mode
Used to write cam programs, set the advance angle compensation
function, etc.
Changing the Mode
PRG
All outputs will remain OFF.
PRG
TST
RUN
Programming Mode
Changed with the mode switch.
Test Mode
PRG
TST
RUN
Used to write cam programs, set the advance angle compensation
function, and perform other operations while actually turning ON
outputs to confirm operation timing. This mode is also used to adjust
settings during operation.
TST
Test Mode
Changed with the mode switch.
Run Mode
PRG
TST
RUN
RUN
Run Mode
Used for normal operation. Settings, such as writing cam programs
and setting the advance angle compensation function, cannot be
performed.
ADV
Key
ON/OFF Key
1 s min.
5 s min.
All Protection
Switching the Angle
and Speed Display
Disables all keys
and switches.
will light when the all
protection function is
enabled.
Main Display: Angle
Sub-display: Speed
↓ ↑
Main Display: Speed
Sub-display: Angle
➾
Refer to page 24.
➾
Refer to page 24.