H8PS  
Setting Resolution and Rotation  
Direction  
One of three resolutions can be selected for the Encoder connected  
to the H8PS: 256, 360, or 720. The resolution and display angle are  
set here.  
Setting the Origin  
The origin of the Cam Positioner is set to match the origin of the  
machine (Encoder). The same origin is used for all banks.  
(The bank function is supported only for 16-/32-output models.)  
Example: Setting the Present Angular Position of 150° to 0°  
Turn OFF the power supply.  
Change the mode.  
Set the mode switch to PRGM.  
Set the display angle and the  
Encoder resolution.  
Set the programming  
mode switch.  
Set the programming mode switch to TCH.  
Open the front cover at the lower part of the H8PS and  
set pins 3 and 4 on the DIP switch.  
Mode  
Programming mode  
PRG  
TST  
RUN  
TCH  
MAN  
CW  
Display  
angle  
1234  
3
4
Resolution  
ON ON 256 256  
ON OFF 256 360  
OFF ON 360 360  
OFF OFF 720 360  
ON  
(See note 2.)  
OFF  
Set the machine to its origin.  
CCW  
Not used.  
Turn the machine (Encoder) to the position of the desired  
origin (150° in this example).  
Note 1: Default settings are shown in reverse type.  
PRG  
Note 2: When using an Encoder with a resolution of 256, displaying 360°  
directly is not possible. The H8PS thus provides a convenient  
setting that enables converting the display and settings to 360°  
when using an Encoder with a resolution of 256. When using a  
360° display, however, some angles will not be displayed.  
Check the rotation direction of the machine (Encoder).  
Turn ON the power supply.  
STEP  
CAM  
Turn the Encoder in the actual direction of operation and  
confirm that the rotation display monitor turns clockwise.  
If the monitor turns counterclockwise, turn OFF the power supply  
and change pin 1 on the DIP switch to CCW.  
Specify the origin.  
Press the ORIGIN Key. (See note.)  
In approx. 1 s, the present angular position display will  
change to 0° and the previous display will return.  
CW  
Rotation Display Monitor  
Display  
(See note.)  
1234  
Resolution  
PRG  
3
4
angle  
ON ON 256 256  
ON OFF 256 360  
OFF ON 360 360  
OFF OFF 720 360  
ON  
OFF  
CCW  
Not used.  
Note: Default setting.  
STEP  
CAM  
Note: With 16-/32-output models, the origin input  
from the terminal block can be turned ON to  
specify the origin.  
Connect the machine (Encoder) and turn ON  
the power supply.  
End  
End of preparations.  
Note: Changes to DIP switch settings are enabled when the power is turned ON.  
21  
 复制成功!