H8PS  
Do not subject H8PS Connectors (outputs, Encoder) to more than  
Precautions for Correct Use  
30 N of force.  
A cam output will remain ON if the set angles for two steps overlap  
Confirm the waveform of the power supply circuit and install a  
surge absorber. Surge or noise applied to the power supply may  
destroy internal elements or cause malfunctions.  
Switch the power supply circuit with a device rated at 3.5 A or  
higher.  
for the same cam number.  
Step 1: 120° ON 170° OFF  
Step 2: 150° ON 210° OFF  
ON  
Inrush current of approximately 3.5 A will flow for a short period of  
time when the power supply is turned ON. The H8PS may not start  
if the capacity of the power supply is not sufficient. Be sure to use a  
power supply with sufficient capacity.  
OFF  
120°  
150° 170°  
210°  
A step will produce no output if the ON and OFF angle for the step  
are the same.  
EEPROM is used as memory when the power is interrupted. The  
write life of the EEPROM is 100000 writes. The EEPROM is written  
when settings are changed or deleted or when the resolution is  
changed.  
The RUN output does not turn ON during programming.  
RUN/TEST  
Mode Switch  
PRGM  
Make sure that all settings are appropriate for the application.  
Unexpected operation resulting in property damage or accidents  
may occur if the settings are not appropriate.  
Connect all negative () terminals, COM terminals, and Vs  
terminals.  
When using the Y92C-30 Parallel Input Adapter for parallel  
operation, do not connect more than two H8PS Cam Positioners to  
the same Encoder.  
ON  
RUN output  
OFF  
Note: The RUN output turns ON with the timing shown in the diagram,  
but it remains OFF when an error occurs. Thus, you can use the  
output as a timing signal during operation, including trial  
operation.  
Input signals may be accepted, not accepted, or unstable for the  
following times when the power supply is turned ON or OFF. Set the  
system to allow leeway in the timing of input signals. Approx. 1  
second is required from the time the power supply is turned ON  
until outputs are made. Refer to the Operation Manual (Cat. No.  
Z199) for information on other timing.  
ON  
Power  
supply  
OFF  
5 ms 0 to 1 s  
Unstable  
0 to 1.3 s  
Unstable  
Input status  
Accepted  
Not accepted  
When using 16-/32-output Modules, the operation timing of the  
outputs will be as shown below in relation to the ON/OFF timing of  
the start input. Refer to Bank Functions (F7/F8/F9) on page 29  
when switching banks.  
ON  
Start input  
OFF  
225 ms max.  
225 ms max.  
Cam outputs  
RUN output  
Output OFF  
Output possible  
Output OFF  
Refer to the following manual for precautions in using the Cam Positioner and other information required for operation:  
H8PS Cam Positioner Operation Manual (Cat. No. Z199)  