VS1005g Datasheet
10 VS1005 PERIPHERALS AND REGISTERS
TIMER_Tx[L/H] register defines the Timer X Startvalue. The 32-bit start value TIMER_Tx[L/H]
fi
c+1
sets the initial counter value when the timer is reset. The timer interrupt frequency ft =
where fi is the master clock obtained with the clock divider and c is TIMER_Tx[L/H].
TIMER_TxCNT[L/H] contains the current counter values. By reading this register pair, the user
may get knowledge of how long it will take before the next timer interrupt. Also, by writing to
this register, a one-shot different length timer interrupt delay may be realized.
Each timer has its own interrupt, which is asserted when the timer counter underflows.
Version: 0.2, 2012-03-16
93