R
XCR3064A: 64 Macrocell CPLD With Enhanced Clocking
DC Electrical Characteristics For Commercial Grade Devices
Commercial: 0°C ≤ T
≤ +70°C; 3.0V ≤ V ≤ 3.6V
AMB
CC
Symbol
Parameter
Test Conditions
Min.
Max.
Unit
V
Input Voltage low
V
= 3.0V
= 3.6V
IL
CC
0.8
V
V
V
V
V
V
Input Voltage high
Input clamp Voltage
Output Voltage low
Output Voltage high
V
V
V
V
V
V
V
V
V
2.0
IH
I
CC
CC
CC
CC
3
= 3.0V, I = -18 mA
-1.2
0.5
V
IN
= 3.0V, I = 12 mA
V
OL
OH
OL
= 3.0V, I = -12 mA
2.4
-10
-10
V
OH
I
Input leakage current
3-stated output leakage current
Standby current
= 0 to 5.5 V
= 0 to 5.5 V
= 3.6V, T
10
10
µA
µA
µA
mA
mA
mA
I
IN
IN
I
OZ
1
I
I
= 0°C
= 0°C at 1 MHz
= 0°C at 50 MHz
80
CCQ
CC
CC
CC
AMB
AMB
AMB
1, 2
Dynamic current
= 3.6V, T
= 3.6V, T
1
CCD
25
3
I
Short circuit output current
One pin at a time for no longer than 1
second
-50
5
-200
OS
3
C
C
C
Input pin capacitance
T
T
T
= 25°C, f = 1 MHz
= 25°C, f = 1 MHz
= 25°C, f = 1 MHz
8
pF
pF
pF
IN
AMB
AMB
AMB
3
Clock input capacitance
12
10
CLK
3
I/O pin capacitance
I/O
Notes:
1. See Table 1 on page 6 for typical values.
2. This parameter measured with a 16-bit, loadable up/down counter loaded into every logic block, with all outputs disabled
and unloaded. Inputs are tied to VCC or ground. This parameter guaranteed by design and characterization, not testing.
3. This parameter guaranteed by design and characterization, not by test.
DS037 (v1.1) February 10, 2000
www.xilinx.com
10