CALIBRATION  
The internal full-scale calibration word is bypassed  
during offset calibration. Do not exceed +105% of  
full-scale range for gain calibration. Note that the  
out-of-range threshold is unaffected by gain  
calibration.  
The ADS1259 has commands to correct for system  
offset and gain errors. Calibration can be performed  
at any time the ADS1259 and associated circuitry  
(such as the input amplifier, external reference, power  
supplies, etc) have stabilized. Options include  
calibrating after power-up, after temperature changes,  
or calibration at regular intervals. To calibrate:  
Table 15. Calibration Timing  
tCAL CALIBRATION TIME (ms)  
DATA RATE  
(SPS)  
14400  
3600  
1200  
400  
sinc1  
1.89  
5.43  
14.9  
43.2  
284  
sinc2  
2.19  
6.15  
16.7  
48.4  
318  
Set the gate control mode (PULSE bit = 0)  
Start the ADS1259 conversions  
Apply the appropriate input to the ADS1259 (zero  
or full-scale)  
Allow time for the input to completely settle  
Send the OFSCAL (offset calibration) or GANCAL  
(full-scale calibration) command, as appropriate  
60  
50  
341  
380  
Wait for calibration to complete as given by the  
time listed in  
calibration is complete. The conversion result at  
this time uses the new offset or full-scale  
calibration words.  
16.6  
10  
1020  
1700  
1140  
1900  
Table  
15. DRDY goes low when  
1. fCLK = 7.3728MHz.  
Figure  
55  
DRDY  
(DOUT with CS = 0)  
shows the calibration timing. During  
tCAL  
calibration, do not send commands.  
Calibration complete  
and first data ready.  
Perform offset calibration prior to the gain calibration.  
CAL Command  
DIN  
Figure 55. Calibration Timing  
Copyright © 2009–2010, Texas Instruments Incorporated  
Submit Documentation Feedback  
27  
Product Folder Link(s): ADS1259  
 
 
 