欢迎访问ic37.com |
会员登录 免费注册
发布采购

ADS131M04QPWRQ1 参数 Datasheet PDF下载

ADS131M04QPWRQ1图片预览
型号: ADS131M04QPWRQ1
PDF下载: 下载PDF文件 查看货源
内容描述: [汽车类四通道、24 位、64kSPS、同步采样 Δ-Σ ADC | PW | 20 | -40 to 125]
分类和应用:
文件页数/大小: 94 页 / 2718 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号ADS131M04QPWRQ1的Datasheet PDF文件第37页浏览型号ADS131M04QPWRQ1的Datasheet PDF文件第38页浏览型号ADS131M04QPWRQ1的Datasheet PDF文件第39页浏览型号ADS131M04QPWRQ1的Datasheet PDF文件第40页浏览型号ADS131M04QPWRQ1的Datasheet PDF文件第42页浏览型号ADS131M04QPWRQ1的Datasheet PDF文件第43页浏览型号ADS131M04QPWRQ1的Datasheet PDF文件第44页浏览型号ADS131M04QPWRQ1的Datasheet PDF文件第45页  
ADS131M04-Q1  
ZHCSOL7A MARCH 2022 REVISED AUGUST 2022  
www.ti.com.cn  
8.5.1.10 Commands  
8-11 contains a list of all valid commands, a short description of their functionality, their binary command  
word, and the expected response that appears in the following frame.  
8-11. Command Definitions  
COMMAND  
NULL  
DESCRIPTION  
COMMAND WORD  
0000 0000 0000 0000  
0000 0000 0001 0001  
0000 0000 0010 0010  
RESPONSE  
No operation  
STATUS register  
RESET  
Reset the device  
1111 1111 0010 0100  
0000 0000 0010 0010  
STANDBY  
Place the device into standby mode  
Wake the device from standby mode to conversion  
mode  
WAKEUP  
0000 0000 0011 0011  
0000 0000 0011 0011  
Lock the interface such that only the NULL, UNLOCK,  
and RREG commands are valid  
LOCK  
0000 0101 0101 0101  
0000 0110 0101 0101  
0000 0101 0101 0101  
0000 0110 0101 0101  
UNLOCK  
Unlock the interface after the interface is locked  
dddd dddd dddd dddd  
or  
Read nnn nnnn plus 1 registers beginning at address a  
aaaa a  
RREG  
WREG  
101a aaaa annn nnnn  
011a aaaa annn nnnn  
111a aaa annn nnnn (1)  
Write nnn nnnn plus 1 registers beginning at address a  
aaaa a  
010a aaaa ammm mmmm  
(2)  
(1) When nnn nnnn is 0, the response is the requested register data dddd dddd dddd dddd. When nnn nnnn is greater than 0, the  
response begins with 111a aaaa annn nnnn, followed by the register data.  
(2) In this case mmm mmmm represents the number of registers that are actually written minus one. This value may be less than nnn  
nnnn in some cases.  
8.5.1.10.1 NULL (0000 0000 0000 0000)  
The NULL command is the no-operation command that results in no registers read or written, and the state of  
the device remains unchanged. The intended use case for the NULL command is during ADC data capture. The  
command response for the NULL command is the contents of the STATUS register. Any invalid command also  
gives the NULL response.  
8.5.1.10.2 RESET (0000 0000 0001 0001)  
The RESET command resets the ADC to the register defaults. The command is latched by the device at the end  
of the frame. A reset occurs immediately after the command is latched. The host must wait for tREGACQ after  
reset before communicating with the device to ensure the registers have assumed their default settings. The  
device sends an acknowledgment of FF24h when the ADC is properly RESET. The device responds with 0011h  
if the command word is sent but the frame is not completed and therefore the device is not reset. See the  
RESET Command section for more information regarding the operation of the reset command. 8-22 illustrates  
a properly sent RESET command frame.  
Copyright © 2022 Texas Instruments Incorporated  
Submit Document Feedback  
41  
Product Folder Links: ADS131M04-Q1  
 
 
 
 
 复制成功!