欢迎访问ic37.com |
会员登录 免费注册
发布采购

UPSD3412C-24U6T 参数 Datasheet PDF下载

UPSD3412C-24U6T图片预览
型号: UPSD3412C-24U6T
PDF下载: 下载PDF文件 查看货源
内容描述: 闪存可编程系统设备与8032单片机内核和16Kbit的SRAM [Flash Programmable System Devices with 8032 Microcontroller Core and 16Kbit SRAM]
分类和应用: 闪存静态存储器微控制器
文件页数/大小: 152 页 / 1492 K
品牌: STMICROELECTRONICS [ ST ]
 浏览型号UPSD3412C-24U6T的Datasheet PDF文件第61页浏览型号UPSD3412C-24U6T的Datasheet PDF文件第62页浏览型号UPSD3412C-24U6T的Datasheet PDF文件第63页浏览型号UPSD3412C-24U6T的Datasheet PDF文件第64页浏览型号UPSD3412C-24U6T的Datasheet PDF文件第66页浏览型号UPSD3412C-24U6T的Datasheet PDF文件第67页浏览型号UPSD3412C-24U6T的Datasheet PDF文件第68页浏览型号UPSD3412C-24U6T的Datasheet PDF文件第69页  
UPSD3212C, UPSD3212CV  
More About Modes 2 and 3. Eleven bits are  
transmitted (through TxD), or received (through  
RxD): a Start Bit (0), 8 data bits (LSB first), a pro-  
grammable 9th data bit, and a Stop Bit (1). On  
transmit, the 9th data bit (TB8) can be assigned  
the value of '0' or '1.' On receive, the data bit goes  
into RB8 in SCON. The baud rate is programma-  
ble to either 1/16 or 1/32 the CPU clock frequency  
in Mode 2. Mode 3 may have a variable baud rate  
generated from Timer 1.  
Figure 31, page 66 and Figure 33, page 67 show  
a functional diagram of the serial port in Modes 2  
and 3. The receive portion is exactly the same as  
in Mode 1. The transmit portion differs from Mode  
1 only in the 9th bit of the transmit shift register.  
Transmission is initiated by any instruction that  
uses SBUF as a destination register. The “WRITE  
to SBUF” signal also loads TB8 into the 9th bit po-  
sition of the transmit shift register and flags the TX  
Control unit that a transmission is requested.  
Transmission commences at S1P1 of the machine  
cycle following the next roll-over in the divide-by-  
16 counter. (Thus, the bit times are synchronized  
to the divide-by-16 counter, not to the “WRITE to  
SBUF” signal.)  
The transmission begins with activation of SEND,  
which puts the start bit at TxD. One bit time later,  
DATA is activated, which enables the output bit of  
the transmit shift register to TxD. The first shift  
pulse occurs one bit time after that (see Figure 32,  
page 66 and Figure 34, page 67). The first shift  
clocks a '1' (the Stop Bit) into the 9th bit position of  
the shift register. There-after, only zeros are  
clocked in. Thus, as data bits shift out to the right,  
zeros are clocked in from the left. When TB8 is at  
the out-put position of the shift register, then the  
Stop Bit is just to the left of TB8, and all positions  
to the left of that contain zeros. This condition flags  
the TX Control unit to do one last shift and then de-  
activate SEND and set TI. This occurs at the 11th  
divide-by 16 rollover after “WRITE to SUBF.”  
Reception is initiated by a detected 1-to-0 transi-  
tion at RxD. For this purpose RxD is sampled at a  
rate of 16 times whatever baud rate has been es-  
tablished. When a transition is detected, the di-  
vide-by-16 counter is immediately reset, and 1FFH  
is written to the input shift register.  
At the 7th, 8th, and 9th counter states of each bit  
time, the bit detector samples the value of R-D.  
The value accepted is the value that was seen in  
at least 2 of the 3 samples. If the value accepted  
during the first bit time is not '0,' the receive circuits  
are reset and the unit goes back to looking for an-  
other 1-to-0 transition. If the Start Bit proves valid,  
it is shifted into the input shift register, and recep-  
tion of the rest of the frame will proceed.  
As data bits come in from the right, '1s' shift out to  
the left. When the Start Bit arrives at the left-most  
position in the shift register (which in Modes 2 and  
3 is a 9-bit register), it flags the RX Control block  
to do one last shift, load SBUF and RB8, and set  
RI.  
The signal to load SBUF and RB8, and to set RI,  
will be generated if, and only if, the following con-  
ditions are met at the time the final shift pulse is  
generated:  
1. RI = 0, and  
2. Either SM2 = 0, or the received 9th data bit = 1  
If either of these conditions is not met, the received  
frame is irretrievably lost, and RI is not set. If both  
conditions are met, the received 9th data bit goes  
into RB8, and the first 8 data bits go into SBUF.  
One bit time later, whether the above conditions  
were met or not, the unit goes back to looking for  
a 1-to-0 transition at the RxD input.  
65/152  
 复制成功!