欢迎访问ic37.com |
会员登录 免费注册
发布采购

47N350 参数 Datasheet PDF下载

47N350图片预览
型号: 47N350
PDF下载: 下载PDF文件 查看货源
内容描述: LEGACY免费的键盘嵌入式控制器, SPI和LPC接口对接 [LEGACY FREE KEYBOARD EMBEDDED CONTROLLER WITH SPI AND LPC DOCKING INTERFACE]
分类和应用: 控制器PC
文件页数/大小: 346 页 / 4406 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号47N350的Datasheet PDF文件第40页浏览型号47N350的Datasheet PDF文件第41页浏览型号47N350的Datasheet PDF文件第42页浏览型号47N350的Datasheet PDF文件第43页浏览型号47N350的Datasheet PDF文件第45页浏览型号47N350的Datasheet PDF文件第46页浏览型号47N350的Datasheet PDF文件第47页浏览型号47N350的Datasheet PDF文件第48页  
Legacy-Free Keyboard/Embedded Controller with SPI and LPC Docking Interface  
serial data stream and convert it to a parallel 8 bit word which is transferred to the Receive Buffer  
register. The shift register is not accessible.  
5.1.2  
5.1.3  
Transmit Buffer Register (TB)  
Address Offset = 0H, DLAB = 0, WRITE ONLY  
This register contains the data byte to be transmitted. The transmit buffer is double buffered, utilizing  
an additional shift register (not accessible) to convert the 8 bit data word to a serial format. This shift  
register is loaded from the Transmit Buffer when the transmission of the previous byte is complete.  
Interrupt Enable Register (IER)  
Address Offset = 1H, DLAB = 0, READ/WRITE  
The lower three bits of this register control the enables of the four interrupt sources of the Serial Port  
interrupt. It is possible to totally disable the interrupt system by resetting bits 0 through 3 of this register.  
Similarly, setting the appropriate bits of this register to a high, selected interrupts can be enabled.  
Disabling the interrupt system inhibits the Interrupt Identification Register and disables any Serial Port  
interrupt out of the LPC47N350. All other system functions operate in their normal manner, including  
the Line Status and MODEM Status Registers. The contents of the Interrupt Enable Register are  
described below.  
BIT 0  
This bit enables the Received Data Available Interrupt (and timeout interrupts in the FIFO mode) when  
set to logic "1".  
BIT 1  
This bit enables the Transmitter Holding Register Empty Interrupt when set to logic "1".  
BIT 2  
This bit enables the Received Line Status Interrupt when set to logic "1". The error sources causing  
the interrupt are Overrun, Parity, Framing and Break. The Line Status Register must be read to  
determine the source.  
BIT 3  
This bit enables the MODEM Status Interrupt when set to logic "1". This is caused when one of the  
Modem Status Register bits changes state. This bit is not supported.  
BITS 4 – 7  
These bits are always logic "0".  
5.1.4  
FIFO Control Register (FCR)  
Address Offset = 2H, DLAB = X, WRITE  
This is a write only register at the same location as the IIR. This register is used to enable and clear  
the FIFOs, set the RCVR FIFO trigger level. This write only register has a shadow register at MBX9Bh  
(see Table 17.1, “Mailbox Registers Interface,” on page 191). Note: DMA is not supported.  
BIT 0  
Setting this bit to a logic "1" enables both the XMIT and RCVR FIFOs. Clearing this bit to a logic "0"  
disables both the XMIT and RCVR FIFOs and clears all bytes from both FIFOs. When changing from  
FIFO Mode to non-FIFO (16450) mode, data is automatically cleared from the FIFOs. This bit must be  
a 1 when other bits in this register are written to or they will not be properly programmed.  
BIT 1  
Revision 1.1 (01-14-03)  
SMSC LPC47N350  
DATA2S6HEET