S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet
Preliminary
Register 0x001: S/UNI-ATLAS-3200 Identity / Load Counts
Bit
31:24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Type
Function
Unused
Default
X
0
1
1
1
0
0
1
1
0
0
1
0
0
1
0
1
X
0
1
0
0
0
0
0
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
MKT_NUM[15]
MKT_NUM[14]
MKT_NUM[13]
MKT_NUM[12]
MKT_NUM[11]
MKT_NUM[10]
MKT_NUM[9]
MKT_NUM[8]
MKT_NUM[7]
MKT_NUM[6]
MKT_NUM[5]
MKT_NUM[4]
MKT_NUM[3]
MKT_NUM[2]
MKT_NUM[1]
MKT_NUM[0]
TIP
TYPE[2]
TYPE[1]
TYPE[0]
ID[3]
ID[2]
ID[1]
ID[0]
0
Writing to this register simultaneously loads all the aggregate and per-PHY counts in the Input,
Output, and Bypass SDQ FIFOs, and the counts in the BCIFs. While this load is in progress, the
TIP bit will be logic 1 in this register. When the load is complete, the TIP bit becomes 0.
ID[3:0]
The ID bits can be read to provide a binary number indicating the S/UNI-ATLAS-3200
feature version.
TYPE[2:0]
The TYPE bits can be read to distinguish the S/UNI-ATLAS-3200 from the other members of
the S/UNI-ATLAS-3200 family of devices. “001” in this field indicates the S/UNI-ATLAS,
while “010” indicates the S/UNI-S/UNI-ATLAS-3200.
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990553, Issue 4
154