S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Name  
Description  
Fwd Total Lost  
The Total Lost CLP0 cell count represents the total number of lost CLP0 user data  
cells during a PM session. This count is not dependent on a threshold. That is, the  
Total Lost CLP0 cell count is always incremented by the number of lost CLP0 user  
cells.  
CLP0 (16)  
Bwd Total Lost  
CLP0 (16)  
Transmitted  
The Transmitted CLP0+1 User Cell count represents the number of user cells that  
CLP0+1 User Cells are originated on a monitored connection by the transmitting end point.  
(32)  
If the PM session is configured to source Fwd PM cells, then this count is derived  
from the number of user cells transmitted.  
If the PM session is configured to monitor or terminate PM flows, then this count is  
derived from the difference of the TUC 0+1 fields of successive Backward Reporting  
cells.  
Transmitted CLP0  
User Cells (32)  
The Transmitted CLP0+1 User Cell count represents the number of CLP0 user cells  
that are originated on a monitored connection by the transmitting end point.  
If the PM session is configured to source Fwd PM cells, then this count is derived  
from the number of CLP0 user cells transmitted.  
If the PM session is configured to monitor or terminate PM flows, then this count is  
derived from the difference of the TUC0 fields of successive Backward Reporting  
cells.  
Bwd Lost Bwd PM  
Cells (8)  
If the MCSN of a received BwdPM cell is out of sequence, then this count will be  
incremented by the difference between the expected MCSN and the received  
MCSN.  
Bwd Lost Fwd PM  
Cells (8)  
The Bwd Lost Fwd PM Cells count represents the number of forward monitoring  
cells lost in transit to the far end point. This calculation is performed based on the  
Fwd MCSN field of arriving Backwards Reporting cells. Whenever the FMCSN field  
of the Bwd PM cell is out of sequence, this count is incremented by the difference  
between the received and expected MCSN. However, if the Bwd PM cell’s own  
MCSN is also out of sequence, this count will increment by the number of apparently  
lost Fwd PM cells minus the number of lost Bwd PM cells.  
PM Cell Format as defined by ITU-T I.610  
Header Fields  
5x8  
OAM Cell Type OAM Function  
Performance  
Management  
Function  
Reserved  
6
EDC  
(= 0010)  
4
Type  
4
(CRC-10)  
10  
Specific Fields  
45x8  
The Performance Management Function Specific Fields are listed below:  
Fwd = Forward Monitoring PM cell field  
Bwd = Backward Reporting PM cell field  
Fwd + Fwd + Bwd Fwd  
Bwd  
Fwd +  
Bwd  
Fwd  
Bwd  
Bwd  
Bwd  
Bwd  
Bwd  
MCSN TUC_0+1 BEDC_0+1 TUC_0  
(8) (16) (16) (16)  
Time  
Unused Fwd  
SECBC TRCC_0 Block TRCC_0+1  
Stamp 6AH  
MCSN (8)  
(8)  
(16)  
Error  
Result  
(8)  
(16)  
(32)  
(27  
octets)  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  
128  