S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Name  
Description  
Fwd SECB Lost (8) Severely Errored Cell Block Lost Cells. When CLP0_SECBs_Only is a logic 0, the  
Bwd SECB Lost (8) SECB Lost is incremented whenever the number of Lost CLP0+1 cells exceeds  
MLOST in the selected threshold register. When CLP0_SECBs_Only is a logic 1,  
SECB Lost is incremented whenever the number of Lost plus Tagged CLP0 cells  
exceeds MLOST. The accumulation of SECB Lost inhibits the accumulation of the  
count of Lost CLP0 and Lost CLP0+1 cells.  
Fwd SECB  
Severely Errored Cell Block Misinserted Cells (CLP0+1). The SECB Misinserted is  
incremented whenever the number of Misinserted cells exceeds MMISINS in the  
selected threshold register. The accumulation of SECB Misinserted inhibits the  
accumulation of the count of Misinserted Cells.  
Misinserted (8)  
Bwd SECB  
Misinserted(8)  
Fwd SECBC (8)  
Forward Severely Errored Cell Blocks Combined. This running counter increments  
each time a SECB is declared. This value is inserted into the SECBC field of  
generated Backwards Reporting cells.  
Bwd SECBC (8)  
Backward Severely Errored Cell Blocks Combined. This value is copied from the  
SECBC field of received Backwards Reporting cells, and represents a rolling  
modulo-256 count of all Severely Errored Cell Blocks. There is no need to initialize  
this running counter.  
Bwd SECBC  
Accum. (8)  
Backward Accumulating SECBC Count. Whenever a received Bwd PM cell has a  
SECBC field different from the stored Bwd SECBC, this field is incremented by the  
modulo-256 difference. This is a saturating counter that initializes itself when the  
first Bwd PM cell is received.  
Fwd Lost Fwd PM  
Cells (8)  
The Fwd Lost Fwd PM Cells count uses the MCSN of received Forward Monitoring  
cells to determine the number of lost Fwd PM cells. Whenever the MCSN of a  
received Fwd PM cell is out of sequence, this count is incremented by the difference  
between the expected and received MCSN, and BIP-16 calculations are  
suppressed.  
Fwd Tagged CLP0  
Cells (16)  
Whenever there are less CLP0 cells received than were transmitted (TUCD is  
negative) then those cells have either been lost or tagged. The inference is made  
that if CLP0 cells were lost, then they should be lost from the CLP0+1 stream as  
well. Thus when TUCD0 < 0, the Lost CLP0 cells count is incremented by the lesser  
of –TUCD0 and -TUCD0+1, and the Tagged CLP0 Cell Count is incremented by (-  
TUCD0) – (-TUCD0+1), so long as the result is positive. This count is not  
incremented if the SECB Lost or SECB Misins count is incremented.  
Bwd Tagged CLP0  
Cells (16)  
Fwd Lost CLP0  
(16)  
The Lost CLP0 Cell Count represents the total number of Lost CLP0 user cells  
during a PM session. The Lost CLP0 cell count is incremented by the lesser of -  
TUCD_0 and –TUCD_0+1, whenever that number is greater than zero. This count is  
not incremented if the SECB Lost count is incremented.  
Bwd Lost CLP0  
(16)  
Fwd Lost CLP0+1  
(16)  
The Lost CLP0+1 Cell Count represents the total number of Lost CLP0+1 user cells  
during a PM session. The Lost CLP0+1 cell count is incremented by the number of  
Lost CLP0+1 cells, whenever TUCD_0+1 < 0 . This counter will not increment is the  
SECB Lost counter increments (it is therefore sensitive to CLP0_SECBs_only).  
Bwd Lost CLP0+1  
(16)  
Fwd Misinserted  
The Misinserted Cell Count represents the total number of Misinserted CLP0+1 user  
cells during a PM session. The Misinserted Cell Count is incremented by the  
number of misinserted CLP0+1 cells, whenever MMISINSTUCD_0+1 > 0. (i.e. this  
count is not incremented if the SECB Misinserted Count is incremented).  
Cells (16)  
Bwd Misinserted  
Cells (16)  
Fwd Total Lost  
CLP0+1 (16)  
Bwd Total Lost  
CLP0+1 (16)  
The Total Lost CLP0+1 cell count represents the total number of lost CLP0+1 user  
data cells during a PM session. This count is not dependent on a threshold. That  
is, the Total Lost CLP0+1 cell count is always incremented by the number of lost  
CLP0+1 user cells.  