S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
The intention is that the microprocessor use these rollover entries to maintain the most-significant  
bits of the counters in its own memory. The least-significant bits can be accessed by the  
microprocessor in the normal way whenever precise counts are needed. Maskable interrupts are  
provided when the Rollover FIFO is not empty, when it is half full, and when it is nearly full.  
There are four possible sources of Rollover FIFO entries: Per-VC counts, Per-PHY counts, PM  
session 2, or PM session 1. The source of the entry determines its format, and is determined by  
the setting of bits 30:29 of the entry. The most significant bit of the Source field is reserved for  
future use. Each source has an associated Rollover FIFO Enable bit to control whether entries are  
permitted from that source.  
Per-VC counts include the 32-bit general cell counts and the 16-bit Policing Non-Compliant  
counts. The format of a Per-VC rollover FIFO entry is as follows:  
Table 35 Count Rollover FIFO Format For Per-VC Count Entries  
Bit  
Field  
Description  
31  
Reserved  
30:29  
28  
27:12  
Source  
Reserved  
Address  
“00” for a per-VC count entry  
The 16-bit VC Record address that generated this entry  
11:7  
6
5
4
3
Unused  
Non-Compliant 3  
Non-Compliant 2  
Non-Compliant 1  
Alternate Count2  
Alternate Count1  
Count2  
When ‘1’, Policing Non-Compliant Count 3 had its MSB set.  
When ‘1’, Policing Non-Compliant Count 2 had its MSB set.  
When ‘1’, Policing Non-Compliant Count 1 had its MSB set.  
When ‘1’, per-VC Alternate Count 2 had its MSB set  
When ‘1’, per-VC Alternate Count 1 had its MSB set  
When ‘1’, per-VC Count 2 had its MSB set  
2
1
0
Count1  
When ‘1’, per-VC Count 1 had its MSB set  
Per-PHY counts include Per-PHY policing counts and the per-PHY counts of received CLP0  
cells, CLP1 cells, etc. The format of a per-PHY rollover FIFO entry is as follows:  
Table 36 Count Rollover FIFO Format For Per-PHY Count Entries  
Bit  
31  
Field  
Reserved  
Description  
30:29  
28:23  
22:11  
10  
Source  
PHY Address  
Unused  
TIMEOUT  
EFCI_NZGFC  
“01” for a per-PHY count entry  
The 6-bit PHY address that generated this entry  
When ‘1’, the MSB of the Timed-Out Cell Count was set.  
When ‘1’, the MSB of the EFCI/Non-Zero GFC Cell Count was set.  
9
8
Invalid  
When ‘1’, the PHY Invalid VPI/VCI/PTI (Search Error, Unprovisioned  
VPI_VCI_PTI  
or Inactive connection, or Reserved VCI/PTI) count had its MSB set.  
7
Bad OAM_RM  
When ‘1’, the PHY Errored RM/OAM cells count had its MSB set.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  
131  