欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7325-TC 参数 Datasheet PDF下载

PM7325-TC图片预览
型号: PM7325-TC
PDF下载: 下载PDF文件 查看货源
内容描述: S / UNI - ATLAS -3200电信标准产品数据表初步 [S/UNI-ATLAS-3200 Telecom Standard Product Data Sheet Preliminary]
分类和应用: ATM集成电路SONET集成电路SDH集成电路电信电路异步传输模式
文件页数/大小: 432 页 / 2222 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7325-TC的Datasheet PDF文件第128页浏览型号PM7325-TC的Datasheet PDF文件第129页浏览型号PM7325-TC的Datasheet PDF文件第130页浏览型号PM7325-TC的Datasheet PDF文件第131页浏览型号PM7325-TC的Datasheet PDF文件第133页浏览型号PM7325-TC的Datasheet PDF文件第134页浏览型号PM7325-TC的Datasheet PDF文件第135页浏览型号PM7325-TC的Datasheet PDF文件第136页  
S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Bit  
6
5
4
3
Field  
RM  
OAM  
CLP1  
CLP0  
Description  
When ‘1’, the PHY Valid RM cells count had its MSB set.  
When ‘1’, the PHY Valid OAM cells count had its MSB set.  
When ‘1’, the PHY CLP1 cells count had its MSB set.  
When ‘1’, the PHY CLP0 cells count had its MSB set.  
When ‘1’, PHY Policing Non-Compliant Count 3 had its MSB set.  
2
PHY Non-  
Compliant 3  
1
0
PHY Non-  
When ‘1’, PHY Policing Non-Compliant Count 2 had its MSB set.  
When ‘1’, PHY Policing Non-Compliant Count 1 had its MSB set.  
Compliant 2  
PHY Non-  
Compliant 1  
PM counts include Forward Lost CLP0 Cells, Backward Lost CLP0+1 Cells, etc.  
Table 37 Count Rollover FIFO Format For PM Entries  
Bit  
31  
Field  
Reserved  
Description  
30:29  
Source  
“010” for a PM count entry from PM Bank 0, “011” for a PM  
count entry from PM Bank 1  
28:21  
20  
PM Address  
PM Direction  
The 8-bit PM Session address that generated this entry  
When PM Direction is ‘1’, the counts indicated refer to Forward  
counts accumulated by the transmission or reception of Fwd  
PM cells. When PM Direction is ‘0’, the counts indicated refer  
to Backward counts accumulated by the reception of Bwd PM  
cells.  
19  
PM Source  
When PM Source is logic 1, then the PM session is a PM flow  
source point, and only the Transmitted CLP0 and Transmitted  
CLP0+1 count indications are valid.  
18:17  
16  
Reserved  
Fwd/Bwd Errors  
When ‘1’, the Fwd or Bwd Errored Cell Count had its MSB set,  
depending on the setting of the PM Direction bit. Because this  
count may roll over quite frequently, there is a register bit,  
Sat_Fast_PM_Counts, which forces this error count to  
saturate, and not generate Count Rollover FIFO entries.  
15  
14  
Fwd/Bwd Impaired  
When ‘1’, the Fwd or Bwd Impaired Block count had its MSB  
set, depending on the setting of the PM Direction bit.  
Fwd/Bwd Lost/Misins  
Impaired  
When ‘1’, the Fwd or Bwd Impaired Blocks due to Lost or  
Misinserted Cells count had its MSB set, depending on the  
setting of the PM Direction bit.  
13  
12  
11  
Fwd/Bwd SECB  
Errored  
When ‘1’, the Fwd or Bwd Severely Errored Cell Block due to  
BIP-16 Errors count had its MSB set, depending on the setting  
of the PM Direction bit.  
When ‘1’, the Fwd or Bwd Severely Errored Cell Block due to  
Lost Cells count had its MSB set, depending on the setting of  
the PM Direction bit.  
When ‘1’, the Fwd or Bwd Severely Errored Cell Block due to  
Misinserted Cells count had its MSB set, depending on the  
setting of the PM Direction bit.  
Fwd/Bwd SECB Lost  
Fwd/Bwd SECB  
Misinserted  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  
132  
 复制成功!