S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Name  
Description  
Bwd TRCC_0+1  
Total Received CLP0+1 User Cell Count for Backwards Reporting cells. This field  
stores the TRCC_0+1 value received from the most recent Backwards Reporting  
cell, and is used along with the TRCC_0+1 field of newly received Backwards  
reporting cells to determine the number of user cells received by the far end point  
between successive Forwards Monitoring cells. This count will be initialized  
automatically on reception of the first Bwd PM cell.  
(16)  
Bwd TUC_0 (16)  
Total CLP0 User Cell Count for Backwards Reporting PM Cells. This field stores the  
value of TUC_0 received from the most recent Backwards Reporting cell, and is  
used with a newly received Bwd PM cell’s TUC_0 to determine the number of cells  
transmitted by the Forward Monitoring source point between successive Forward  
PM cells. This count will be initialized automatically on reception of the first Bwd PM  
cell.  
Bwd TUC_0+1  
(16)  
Total CLP0+1 User Cell Count for Backwards Reporting PM Cells. This field stores  
the value of TUC_0+1 received from the most recent Backwards Reporting cell, and  
is used with a newly received Bwd PM cell’s TUC_0+1 to determine the number of  
cells transmitted by the Forward Monitoring source point between successive  
Forward PM cells. This count will be initialized automatically on reception of the first  
Bwd PM cell.  
Bwd FMCSN (8)  
Bwd BMCSN (8)  
This field contains the Fwd MCSN copied from the most recently received  
Backwards Reporting cell. It is used to infer the loss of Forward Monitoring cells at  
the far end point. If the Bwd FMCSN is out of sequence, then the Bwd Lost Fwd  
PM Cells count is incremented by the number of lost Fwd PM cells, which is  
presumed to be equal to the change in FMCSN less the change in BMCSN. Any  
inference of SECBs due to lost Fwd PM cells is left up to the management software.  
This field contains the MCSN copied from the most recently received Backwards  
Reporting cell. It is used to infer the loss of Backwards Reporting cells. If the  
received Backwards Reporting MCSN is out of sequence, then the Bwd Lost Bwd  
PM Cells Count will be incremented by the number of missed MCSNs. All other  
processing will proceed as normal.  
Fwd Errored Cell  
Count (8)  
The Errored Cell Count represents the number of BIP-16 violations (BIPV) during a  
PM session (on CLP0+1 cells). The Errored Cell counter is incremented whenever  
the number of BIPV is greater than 0 and less than MERROR in the selected  
threshold register, so long as there are no lost or misinserted cells, and the MCSNs  
are in sequence.  
Bwd Errored Cell  
Count (8)  
Fwd Impaired  
Blocks (8)  
The Impaired Block count represents the sum of PM cell blocks containing at least  
one BIP error, lost cell or misinserted cell (CLP0+1  
Bwd Impaired  
Blocks (8)  
Fwd Lost/  
The Lost/Misinserted Impaired Block count represents the sum of the PM cell blocks  
for which there was at least one lost or misinserted cell (CLP0+1). The  
Misinserted  
Impaired Blocks (8) Lost/Misinserted Block Impaired Block count is incremented whenever there is a  
Bwd Lost/  
non-zero TUCD_0+1.  
Misinserted  
Impaired Blocks (8)  
Fwd SECB Errored Severely Errored Cell Block Errored Cells (CLP0+1). The SECB Errored is  
(8) incremented whenever the number of BIPV errors exceeds MERROR in the  
Bwd SECB Errored selected threshold register, and there are no lost/misinserted cells, and the MCSNs  
(8)  
are in sequence. The accumulation of SECB Errored inhibits the accumulation of  
the count of BIP Errors.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  
126  