S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Name  
Fwd TUC_0 (16)  
Description  
Total CLP0 User Cells for Forward Monitoring PM Cells. TUC_0 indicates the  
number modulo 65536 of CLP 0 user cells transmitted just before the transmission  
of a Forward PM cell.  
If this PM process is the source of Forward PM cells then this field stores the value  
of TUC_0 inserted into the most recent generated Forward PM Cell, and is used  
together with the Current Cell Count CLP0 to determine TUC_0 of the subsequent  
generated PM cell. This is a running count and does not need to be initialized.  
If this PM process terminates/monitors Forward PM cells, then this field stores the  
value of TUC_0 received from the most recent Forward PM cell, and is used with the  
received PM cell’s TUC_0 to determine the number of CLP0 user cells transmitted  
between successive Forward PM cells. This count will be initialized automatically on  
reception of the first Forward Monitoring cell. When not a monitor point, Fwd TUC_0  
will be inserted in the TUC_0 field of generated Backwards Reporting cells.  
Fwd TUC_0+1 (16) Total CLP0+1 User Cells. TUC_0+1 indicates the total number modulo 65536 of  
CLP0 and CLP1 user cells transmitted just before the transmission of a Forward PM  
cell.  
If this PM process is the source of Forward PM cells then this field stores the value  
of TUC_0+1 inserted into the most recent generated Forward PM Cell, and is used  
together with the Current Cell Count CLP0+1 to determine TUC_0+1 of the  
subsequent generated PM cell. This is a running count and does not need to be  
initialized.  
If this PM process terminates/monitors Forward PM cells, then this field stores the  
value of TUC_0+1 received from the most recent Forward PM cell, and is used with  
the received PM cell’s TUC_0+1 to determine the number of user cells transmitted  
between successive Forward PM cells. This count will be initialized automatically on  
reception of the first Forward Monitoring cell. When not a monitor point, Fwd  
TUC_0+1 will be inserted in the TUC_0+1 field of generated Backwards Reporting  
cells.  
Fwd FMCSN  
The Forward PM Cell Sequence Number. This field contains the sequence number  
modulo 256 of the most recent Forward Monitoring cell generated/received. The  
MCSN is incremented for each PM cell generated/received during the PM session.  
When Forward PM cells are terminated or monitored, the Fwd MCSN is used to  
identify lost Forward PM cells.  
If the Fwd FMCSN is out of sequence, then BIP-16 calculations are not done, the Bit  
Error Code is sent as all-ones in the Backwards Reporting cell, and the Fwd Lost  
Fwd PM Cells counter is incremented by the number of lost Fwd PM cells. The  
calculation and reporting of lost, misinserted, and tagged cells, impaired blocks, and  
SECBs proceeds as normal. Any inference of SECBs due to lost Fwd PM cells is  
left up to the management software.  
Fwd BMCSN  
The Forward Bwd PM Monitoring Cell Sequence Number is used to determine the  
MCSN for generated Backwards Reporting cells. The Fwd BMCSN value is  
incremented each time a Backwards Routing cell is generated. There is no need to  
initialize this running count.  
Bwd TRCC_0 (16)  
Total Received Cell Count CLP0 for Backwards Reporting cells. This field stores  
the TRCC_0 value received from the most recent Backwards Reporting cell, and is  
used along with the TRCC_0 field of newly received Backwards reporting cells to  
determine the number of CLP0 user cells received by the far end point between  
successive Forwards Monitoring cells. This count will be initialized automatically on  
reception of the first Bwd PM cell.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  