S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Table 32 PM Table Configuration Field  
Bit  
15  
Name  
Source_FwdPM  
Description  
If this bit is a logic 1, the PM session is configured to source a PM flow,  
and a Forward Monitoring cell is output from the S/UNI-ATLAS-3200  
once per block of user cells (nominally). Received Forward Monitoring  
and Backwards Reporting cells will not be processed by this PM  
session. If the session is an F4 session, then any generated F5 Fwd  
PM cells, AIS cells, or CC cells will be included in the user cell flow.  
If the Source_FwdPM bit is a logic 0, then the PM session is configured  
to process received Forward Monitoring and Backwards Reporting cells.  
Termination of PM cells depends only on whether the S/UNI-ATLAS-  
3200 is configured as an end-to-end or segment end point.  
14  
Generate_BwdPM  
If this bit is a logic 1 and the Source_FwdPM bit is a logic 0, a Backward  
Reporting PM cell is generated when an appropriate Forward  
Monitoring PM cell is received. The F4_F5B and ETE_SegB bits  
determine the type of Forward Monitoring cells that are processed, and  
thus the type of Backward Reporting cell that is generated. If the  
Fwd_PM0 bit is a logic 1, then a Backward Reporting cell will not be  
generated (the Fwd_PM0 bit is cleared upon receipt of the first Forward  
Monitoring PM cell).  
13  
12  
F4_F5B  
If this bit is a logic 1, this PM address is for a F4 (VPC) PM flow. F5  
cells, including OAM cells, are user cells as far as this flow is  
concerned.  
If this bit is a logic 0, the PM address is for a F5 (VCC) PM flow. F4  
OAM cells are ignored.  
ETE_SegB  
If this bit is a logic 1, this PM address is for an end-to-end PM flow.  
Segment PM cells are ignored.  
If this bit is a logic 0, this PM address is for a segment PM flow. End-to-  
end PM cells are ignored.  
Despite the setting of this bit, F5 OAM cells are treated as user cells if  
the F4_F5B bit is logic 1.  
11  
Force_FwdPM  
This bit controls the forced insertion of a Forward Monitoring PM cell  
when the S/UNI-ATLAS-3200 is configured to insert Forward Monitoring  
PM cells. When the Force_FwdPM bit is logic 1, the S/UNI-ATLAS-  
3200 will force the insertion of a Forward Monitoring PM cell when the  
current cell count of CLP0+1 cells reaches N+N/2, where N is the  
programmed block size, regardless of the state of the Forward PM  
Pacing register. If this bit is logic 0, then the S/UNI-ATLAS-3200 will  
not insert a Forward Monitoring PM cell unless the Forward PM Pacing  
register allows for a PM cell to be inserted. This bit has no effect when  
Source_FwdPM is logic 0.  
[10:9] Threshold_Select[1:0]  
These bits are used to index one of four possible threshold selection  
register pairs (PM Threshold A1/A2 through PM Threshold D1/D2)  
which hold the threshold values for Errored, Misinserted and Lost  
Severely Errored Cell Blocks.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  