ML53612 ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––  
Configuration Register Byte 1, AR = 0001h  
DR_0  
C
[9:8]  
10  
Definition  
[1:0]  
Slave Bus Mode [1:0]  
Slave Local Timing Source Select  
Advance Slave PLL Timing  
Slave CT Manual/Auto Mode  
Slave CT A/B Select  
2
3
4
5
6
7
11  
12  
13  
14  
Slave CT A/B Read-back  
Reserved  
15  
[1]  
Slave Bus Mode [1:0] (C_ [9:8]) (Read/Write)  
00  
01  
10  
11  
CT Bus - Slave to CT_C8 & CT_FRAME (see Slave CT A/B Select) (Default)  
SCbus - Slave to SCLK & FR_COMP  
MVIP - Slave to C2 & FR_COMP  
Local - Slave to L_CLK & L_FS (see Slave Local Timing Source Select)  
1. When local slave mode is selected, L_CLK frequency, polarity and output enable, and L_FS polarity, position and output enable must be configured  
accordingly.  
Slave Local Timing Source Select (C_ [10]) (Read/Write)  
0
1
L_CLK_0, L_FS_0 (Default)  
L_CLK_1, L_FS_1  
Advance Slave PLL Timing (C_ [11]) (Read/Write)  
The slave PLL timing may be advanced one 7.6 ns period to compensate for delay. Set to 0 for normal operation.  
0
1
Advance Slave PLL Timing Disabled (Default)  
Advance Slave PLL Timing Enabled  
[1]  
Slave CT Manual/Auto Mode (C_ [12]) (Read/Write)  
0
1
Slave CT Manual Mode (Default)  
Slave CT Auto Mode  
1. In auto mode, slave will only switch when an error exists on the current signal set and NOT on the other signal set.  
Slave CT A/B Select (C_ [13]) (Read/Write)  
Select signal set in manual mode then switch to auto.  
0
1
CT A Select (Default)  
CT B Select  
Slave CT A/B Read-back (C_ [14]) (Read Only)  
0
1
CT A Selected  
CT B Selected  