Preliminary Information  
MT9076  
Bit  
Name  
Functional Description  
7
FERRI  
Errored Framing Alignment Signal Interrupt. When unmasked this interrupt bit goes  
high whenever an erroneous bit in frame alignment signal is detected (provided the  
circuit is in terminal frame sync). Reading this register clears this bit.  
6
5
4
3
CRCERRI CRC-4 Error Interrupt. When unmasked this interrupt bit goes high whenever a local  
CRC-4 error occurs. Reading this register clears this bit.  
EBITI  
AIS16I  
LCVI  
Receive E-bit Error Interrupt. When unmasked this interrupt bit goes high upon  
detection of a wrong E-bit in multiframe. Reading this register clears this bit.  
Alarm Indication Signal Interrupt. When unmasked this interrupt bit goes high  
whenever all ones in time slot 16 occur.Reading this register clears this bit.  
Bipolar Violation Interrupt. When unmasked this interrupt bit goes high whenever a  
line code violation (excluding HDB3 encoding) is encountered. Reading this register  
clears this bit.  
2
1
0
PRBSERRI Pseudo Random Bit Sequence Error Interrupt. When unmasked this interrupt bit  
goes high upon detection of an error with a channel selected for PRBS testing. Reading  
this register clears this bit.  
AUXPI  
Auxiliary Pattern Alarm Interrupt. When unmasked this interrupt bit goes high  
whenever a sequence of 512 bit consecutive 101010. occur. Reading this register  
clears this bit.  
RAII  
Remote alarm Indication Interrupt. When unmasked this interrupt bit goes high  
whenever the bit 3 of non-frame alignment signal is high. Reading this register clears  
this bit.  
Table 145 - Interrupt Word One  