fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588  
Data Sheet  
April 10, 2013  
9.2.4 Accumulator Register  
Mnemonic  
type offset bits 15  
R/W 0x08  
14  
0
13  
0
12  
0
11  
0
10  
0
9
8
7
6
5
0
5
0
4
0
4
0
3
0
3
0
2
0
2
0
1
0
1
0
0
0
0
0
Accum_Lo  
Accumulator[15:0]  
Power-up Defaults  
0
0
9
0
8
0
7
0
6
Mnemonic  
type offset bits 15  
R/W 0x0A  
14  
0
13  
0
12  
0
11  
0
10  
0
Accum_Hi  
Accumulator[31:16]  
Power-up Defaults  
0
0
0
0
0
The Accumulator register consists of two 16-bit registers. The Accumulator register  
serves as a precision frequency divider in the time synchronization logic. Firmware  
calculates a frequency scaling value to be written to the Addend register. The data in the  
Accumulator register is added to the value in the Addend register once every period of  
the system clock. When the Accumulator rolls over, an overflow pulse is asserted which  
increments the value in the system timer. This register is not read or written to in normal  
operation. When performing reads, Accum_Lo should be read first, which will cause the  
higher 16 bits of the internal accumulator register to be latched and when Accum_Hi is  
read later, the latched value will be returned. When performing writes, Accum_Lo should  
be written first and when Accum _Hi is written later, the internal accumulator register  
will be updated with the full 32-bit value.  
9.2.5 System Time Register  
Mnemonic  
type offset bits 15  
R/W 0x0C  
14  
0
13  
0
12  
0
11  
0
10  
0
9
0
9
0
9
0
9
0
8
7
6
0
6
0
6
0
6
0
5
0
5
0
5
0
5
0
4
0
4
0
4
0
4
0
3
0
3
0
3
0
3
0
2
0
2
0
2
0
2
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
SysTime_Lo_Lo  
Systime[15:0]  
Power-up Defaults  
0
0
8
0
7
Mnemonic  
type offset bits 15  
R/W 0x0E  
14  
0
13  
0
12  
0
11  
0
10  
0
SysTime_Lo_Hi  
Systime[31:16]  
Power-up Defaults  
0
0
8
0
7
Mnemonic  
type offset bits 15  
R/W 0x10  
14  
0
13  
0
12  
0
11  
0
10  
0
SysTime_Hi_Lo  
Systime[47:32]  
Power-up Defaults  
0
0
8
0
7
Mnemonic  
type offset bits 15  
R/W 0x12  
14  
0
13  
0
12  
0
11  
0
10  
0
SysTime_Hi_Hi  
Systime[63:48]  
Power-up Defaults  
0
0
0