PROFET BTS 740 S2  
Parameter and Conditions, each of the two channels  
Symbol  
Values  
Unit  
at Tj = -40...+150°C, V = 12 V unless otherwise specified  
bb  
min  
typ  
max  
Reverse Battery  
Reverse battery voltage 15)  
-Vbb  
--  
--  
--  
32  
--  
V
Drain-source diode voltage (V > V  
)
-VON  
600  
mV  
out  
bb  
IL =-4.0A, Tj =+150°C  
Diagnostic Characteristics  
Current sense ratio16), static on-condition,  
17)  
= 6.5 ...27V,  
bb(on)  
V
k
= 0...5 V, V  
= I / I  
IS  
Tj = -40°C, IL = 5 A:  
kILIS  
4350 4800 5800  
3100 4800 7800  
ILIS  
L
IS  
Tj= -40°C, IL= 0.5 A:  
Tj= 25...+150°C, IL= 5 A:  
Tj= 25...+150°C, IL = 0.5 A:  
4350 4800 5350  
3800 4800 6300  
Current sense output voltage limitation  
T = -40 ...+150°C  
I
= 0, I = 5 A:  
j
IS L  
VIS(lim)  
5.4  
6.1  
6.9  
V
Current sense leakage/offset current  
T = -40 ...+150°C  
V =0, V = 0, I = 0:  
j
IN IS  
L
IIS(LL)  
IIS(LH)  
IIS(SH)  
0
0
0
--  
--  
--  
1
15  
10  
µA  
V =5 V, V = 0, I = 0:  
IN IS  
L
18)  
V =5 V, V = 0, V  
IN IS  
= 0 (short circuit)  
OUT  
Current sense settling time to IIS static±10% after  
18)  
tson(IS)  
--  
--  
--  
300  
100  
µs  
µs  
positive input slope , I = 0  
5 A  
L
Current sense settling time to 10% of IIS static after  
18)  
negative input slope , I = 5  
0 A  
tsoff(IS)  
30  
L
Current sense rise time (60% to 90%) after change  
18)  
of load current  
I = 2.5  
L
5 A  
tslc(IS)  
VOUT(OL)  
--  
2
10  
3
--  
4
µs  
Open load detection voltage19) (off-condition)  
Internal output pull down  
(pin 17,18 to 2 resp. 13,14 to 6), V  
OUT  
V
=5 V  
RO  
5
15  
40  
kΩ  
15)  
16)  
Requires a 150 resistor in GND connection. The reverse load current through the intrinsic drain-source  
diode has to be limited by the connected load. Power dissipation is higher compared to normal operating  
conditions due to the voltage drop across the drain-source diode. The temperature protection is not active  
during reverse current operation! Input and Status currents have to be limited (see max. ratings page 3 and  
circuit page 9).  
This range for the current sense ratio refers to all devices. The accuracy of the kILIS can be raised at least by  
a factor of two by matching the value of kILIS for every single device.  
In the case of current limitation the sense current IIS is zero and the diagnostic feedback potential VST is  
High. See figure 2c, page 12.  
17)  
18)  
19)  
Valid if Vbb(u rst) was exceeded before.  
not subject to production test, specified by design  
External pull up resistor required for open load detection in off state.  
Semiconductor Group  
6
2003-Oct-01  