Ethernet: Three-Speed,10/100, MII Management
shows the MII receive AC timing diagram.
t
MRX
RX_CLK
t
MRXH
RXD[3:0]
RX_DV
RX_ER
t
MRDVKH
t
MRDXKH
t
MRXF
Valid Data
t
MRXR
Figure 15. MII Receive AC Timing Diagram
8.4 Ethernet Management Interface Electrical Characteristics
The electrical characteristics specified here apply to MII management interface signals MDIO
(management data input/output) and MDC (management data clock). The electrical characteristics for
GMII, RGMII, TBI and RTBI are specified in
8.4.1 MII Management DC Electrical Characteristics
The MDC and MDIO are defined to operate at a supply voltage of 3.3 V. The DC electrical characteristics
for MDIO and MDC are provided in
Table 33. MII Management DC Electrical Characteristics
Parameter
Supply voltage (3.3 V)
Output high voltage
(OV
DD
= Min, I
OH
= –1.0 mA)
Output low voltage
(OV
DD
= Min, I
OL
= 1.0 mA)
Input high voltage
Input low voltage
Input high current
(OV
DD
= Max, V
IN 1
= 2.1 V)
Input low current
(OV
DD
= Max, V
IN
= 0.5 V)
Symbol
OV
DD
V
OH
V
OL
V
IH
V
IL
I
IH
I
IL
Min
3.13
2.10
Max
3.47
OV
DD
+ 0.3
0.50
Unit
V
V
GND
V
1.70
—
—
—
0.90
40
V
V
μA
μA
–600
—
Note:
1.Note that the symbol V
IN
, in this case, represents the OV
IN
symbol referenced in
and
MPC8540 Integrated Processor Hardware Specifications, Rev. 4
34
Freescale Semiconductor