EMD3D256M08BS1
EMD3D256M16BS1
FUNCTIONAL PARAMETERS
Functional
Parameter
Level
Description
It is expected that bit fails will be soft and distributed through-
out the address space so the system ECC built into your control-
ler should correct them. BER is after maximum page cycles, or at
the end of the endurance life.
Bit Error Rate (BER)
Limit to End of Life
-8
6.3 x 10
A cycle is defined as a page access. After this number of cycles,
the bit error rate may start to increase above the BER limit. Sys-
tem level ECC is recommended.
10
Cycle Endurance
Data Retention
1 x10
The data retention time starts from the last read or write cycle
and does not differ between powered up and powered down
conditions.
TOPER = 70°C,
3 months
EMD3D256M08BS1/16BS1 Revision 1.3 10/2018
Copyright © 2018 Everspin Technologies
24