MT90826  
Data Sheet  
Read/Write Address:  
Reset Value:  
0000H,  
0000H.  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
0
DR2  
DR1  
DR0  
BPD2 BPD1 BPD0  
CPLL CBER SBER SFE  
0
BPE MBP  
MS  
OSB  
0
Bit  
Name  
Description  
15 - 13 BPD2-0  
Block Programming Data. These bits carry the value to be loaded into the  
connection memory block whenever the memory block programming feature is  
activated. After the MBP bit is set to 1 and the BPE bit is set to 1, the contents of the  
bits BPD2- 0 are loaded into bit 15 to bit 13 of the connection memory. Bit 12 to bit 0 of  
the connection memory are set to 0.  
12  
11  
Unused  
Must be zero for normal operation.  
CPLL  
PLL Input Frequency Select. When zero or one, the CLK input is 16.384 MHz and  
the F0i input is 60 ns wide. When one, the CLK input is 8.192 MHz and the F0i input is  
122 ns wide. See Table 6 for the usage of the clock frequency.  
10  
9
CBER  
SBER  
Clear Bit Error Rate Register. A zero to one transition in this bit resets the internal  
bit error counter and the bit error count register to zero.  
Start Bit Error Rate Test. A zero to one transition in this bit starts the bit error rate  
test. The bit error test result is kept in the bit error count register. A one to zero  
transition stops the bit error rate test and the internal bit error counter.  
8
SFE  
Start Frame Evaluation. A zero to one transition in this bit starts the frame evaluation  
procedure. When the CFE bit in the frame alignement (FAR) register changes from  
zero to one, the evaluation procedure stops. To start another frame evaluation cycle,  
set this bit to zero.  
7
6
Unused  
BPE  
Must be zero for normal operation.  
Begin Block programming Enable. A zero to one transition of this bit enables the  
memory block programming function. The BPE and BPD2-0 bits have to be defined in  
the same write operation. Once the BPE bit is set high, the device requires two frames  
to complete the block programming. After the programming function has finished, the  
BPE bit returns to zero to indicate the operation is completed. When the BPE = 1, the  
BPE or MBP can be set to 0 to abort the programming operation.  
When BPE = 1, the other bits in the control register must not be changed for two  
frames to ensure proper operation.  
5
MBP  
Memory Block Program. When 1, the connection memory block programming  
feature is ready to program Bit13 to Bit15 of the connection memory. When 0, feature  
is disabled.  
Table 5 - Control Register Bits  