R
Platform Flash In-System Programmable Configuration PROMs
XCF08P, XCF16P,
XCF32P
Symbol
Description
Units
Min
12
12
8
Max
–
BUSY setup time to CLKOUT when VCCO = 3.3V or 2.5V
BUSY setup time to CLKOUT when VCCO = 1.8V
BUSY hold time to CLKOUT when VCCO = 3.3V or 2.5V
BUSY hold time to CLKOUT when VCCO = 1.8V
CE to CLKOUT delay(7) when VCCO = 3.3V or 2.5V
CE to CLKOUT delay(7) when VCCO = 1.8V
OE/RESET to CLKOUT delay(7) when VCCO = 3.3V or 2.5V
OE/RESET to CLKOUT delay(7) when VCCO = 1.8V
CF to CLKOUT delay(7) when VCCO = 3.3V or 2.5V
CF to CLKOUT delay(7) when VCCO = 1.8V
ns
ns
ns
ns
µs
µs
µs
µs
–
TSB
–
–
THB
8
–
0
1
TCEC
TOEC
TCFC
TCDD
0
1
0
1
0
1
0
0
–
CLKOUT to data delay when VCCO = 3.3V or 2.5V(8)
CLKOUT to data delay when VCCO = 1.8V(8)
–
30
30
ns
ns
–
Data setup time to CLKOUT
5
ns
when VCCO = 3.3V or 2.5V with decompression(8)(11)
TDDC
Data setup time to CLKOUT when VCCO = 1.8V with decompression(8)(11)
5
3
ns
ns
Data hold from CLKOUT when VCCO = 3.3V or 2.5V
–
–
Data hold from CLKOUT when VCCO = 1.8V
3
ns
TCOH
Data hold from CLKOUT when VCCO = 3.3V or 2.5V with decompression(11)
Data hold from CLKOUT when VCCO = 1.8V with decompression(11)
EN_EXT_SEL setup time to CF, CE, or OE/RESET when VCCO = 3.3V or 2.5V
EN_EXT_SEL setup time to CF, CE, or OE/RESET when VCCO = 1.8V
EN_EXT_SEL hold time from CF, CE, or OE/RESET when VCCO = 3.3V or 2.5V
EN_EXT_SEL hold time from CF, CE, or OE/RESET when VCCO = 1.8V
REV_SEL setup time to CF, CE, or OE/RESET when VCCO = 3.3V or 2.5V
REV_SEL setup time to CF, CE, or OE/RESET when VCCO = 1.8V
REV_SEL hold time from CF, CE, or OE/RESET when VCCO = 3.3V or 2.5V
REV_SEL hold time from CF, CE, or OE/RESET when VCCO = 1.8V
CLKOUT default (fast) frequency(9)
3
–
ns
3
–
ns
300
300
300
300
300
300
300
300
25
–
ns
TSXT
THXT
TSRV
THRV
FF
–
ns
–
ns
–
ns
–
ns
–
ns
–
ns
–
ns
50
25
25
12.5
MHz
MHz
MHz
MHz
CLKOUT default (fast) frequency with decompression(11)
CLKOUT alternate (slower) frequency(10)
CLKOUT alternate (slower) frequency with decompression(11)
12.5
12.5
6
FS
Notes:
1. AC test load = 50 pF for XCF01S/XCF02S/XCF04S; 30 pF for XCF08P/XCF16P/XCF32P.
2. Float delays are measured with 5 pF AC loads. Transition is measured at 200 mV from steady-state active levels.
3. Guaranteed by design, not tested.
4. All AC parameters are measured with V = 0.0V and V = 3.0V.
IL
IH
5. If T
6. If T
High < 2 µs, T = 2 µs.
HCE
CE
Low < 2 µs, T = 2 µs.
HOE
OE
7. The delay before the enabled CLKOUT signal begins clocking data out of the device is dependent on the clocking configuration. The delay
before CLKOUT is enabled increases if decompression is enabled.
8. Slower CLK frequency option might be required to meet the FPGA data sheet setup time.
9. Typical CLKOUT default (fast) period = 25 ns (40 MHz).
10. Typical CLKOUT alternate (slower) period = 50 ns (20 MHz).
11. When decompression is enabled, the CLKOUT signal becomes a controlled clock output. When decompressed data is available, CLKOUT
toggles at ½ the source clock frequency (either ½ the selected internal clock frequency or ½ the external CLK input frequency). When
decompressed data is not available, the CLKOUT pin is parked High. If CLKOUT is used, then it must be pulled High externally using a
4.7 kΩ pull-up to V
.
CCO
12. When JTAG CONFIG command is issued, PROM drives CF Low for at least the T
minimum.
HCF
DS123 (v2.18) May 19, 2010
www.xilinx.com
Product Specification
22