 浏览型号5962-9473002MXC的Datasheet PDF文件第3页浏览型号5962-9473002MXC的Datasheet PDF文件第4页浏览型号5962-9473002MXC的Datasheet PDF文件第5页浏览型号5962-9473002MXC的Datasheet PDF文件第6页浏览型号5962-9473002MXC的Datasheet PDF文件第8页浏览型号5962-9473002MXC的Datasheet PDF文件第9页浏览型号5962-9473002MXC的Datasheet PDF文件第10页浏览型号5962-9473002MXC的Datasheet PDF文件第11页  
R
XC4000E and XC4000X Series Field Programmable Gate Arrays  
Two fast feed-through paths are available, as shown in  
Figure 1. A two-to-one multiplexer on each of the XQ and  
YQ outputs selects between a storage element output and  
any of the control inputs. This bypass is sometimes used by  
the automated router to repower internal signals.  
Set/Reset  
An asynchronous storage element input (SR) can be con-  
figured as either set or reset. This configuration option  
determines the state in which each flip-flop becomes oper-  
ational after configuration. It also determines the effect of a  
Global Set/Reset pulse during normal operation, and the  
effect of a pulse on the SR pin of the CLB. All three  
set/reset functions for any single flip-flop are controlled by  
the same configuration data bit.  
Control Signals  
Multiplexers in the CLB map the four control inputs (C1 - C4  
in Figure 1) into the four internal control signals (H1,  
DIN/H2, SR/H0, and EC). Any of these inputs can drive any  
of the four internal control signals.  
The set/reset state can be independently specified for each  
flip-flop. This input can also be independently disabled for  
either flip-flop.  
When the logic function is enabled, the four inputs are:  
EC — Enable Clock  
SR/H0 — Asynchronous Set/Reset or H function  
generator Input 0  
DIN/H2 — Direct In or H function generator Input 2  
H1 — H function generator Input 1.  
The set/reset state is specified by using the INIT attribute,  
or by placing the appropriate set or reset flip-flop library  
symbol.  
SR is active High. It is not invertible within the CLB.  
When the memory function is enabled, the four inputs are:  
Global Set/Reset  
EC — Enable Clock  
WE — Write Enable  
D0 — Data Input to F and/or G function generator  
D1 — Data input to G function generator (16x1 and  
16x2 modes) or 5th Address bit (32x1 mode).  
A separate Global Set/Reset line (not shown in Figure 1)  
sets or clears each storage element during power-up,  
re-configuration, or when a dedicated Reset net is driven  
active. This global net (GSR) does not compete with other  
routing resources; it uses a dedicated distribution network.  
6
Each flip-flop is configured as either globally set or reset in  
the same way that the local set/reset (SR) is specified.  
Therefore, if a flip-flop is set by SR, it is also set by GSR.  
Similarly, a reset flip-flop is reset by both SR and GSR.  
Using FPGA Flip-Flops and Latches  
The abundance of flip-flops in the XC4000 Series invites  
pipelined designs. This is a powerful way of increasing per-  
formance by breaking the function into smaller subfunc-  
tions and executing them in parallel, passing on the results  
through pipeline flip-flops. This method should be seriously  
considered wherever throughput is more important than  
latency.  
STARTUP  
GSR  
GTS  
PAD  
Q2  
Q3  
Q1Q4  
IBUF  
To include a CLB flip-flop, place the appropriate library  
symbol. For example, FDCE is a D-type flip-flop with clock  
enable and asynchronous clear. The corresponding latch  
symbol (for the XC4000X only) is called LDCE.  
DONEIN  
CLK  
X5260  
Figure 2: Schematic Symbols for Global Set/Reset  
In XC4000 Series devices, the flip flops can be used as reg-  
isters or shift registers without blocking the function gener-  
ators from performing a different, perhaps unrelated task.  
This ability increases the functional capacity of the devices.  
GSR can be driven from any user-programmable pin as a  
global reset input. To use this global net, place an input pad  
and input buffer in the schematic or HDL code, driving the  
GSR pin of the STARTUP symbol. (See Figure 2.) A spe-  
cific pin location can be assigned to this input using a LOC  
attribute or property, just as with any other user-program-  
mable pad. An inverter can optionally be inserted after the  
input buffer to invert the sense of the Global Set/Reset sig-  
nal.  
The CLB setup time is specified between the function gen-  
erator inputs and the clock input K. Therefore, the specified  
CLB flip-flop setup time includes the delay through the  
function generator.  
Using Function Generators as RAM  
Optional modes for each CLB make the memory look-up  
tables in the F’ and G’ function generators usable as an  
array of Read/Write memory cells. Available modes are  
level-sensitive (similar to the XC4000/A/H families),  
edge-triggered, and dual-port edge-triggered. Depending  
on the selected mode, a single CLB can be configured as  
either a 16x2, 32x1, or 16x1 bit array.  
Alternatively, GSR can be driven from any internal node.  
Data Inputs and Outputs  
The source of a storage element data input is programma-  
ble. It is driven by any of the functions F’, G’, and H’, or by  
the Direct In (DIN) block input. The flip-flops or latches drive  
the XQ and YQ CLB outputs.  