X1243 – Preliminary Information  
CONTROL REGISTERS  
A match of the RTC and the contents of the alarm 1  
registers automatically sets the AL1 bit. If the AL1E bit  
is also set, the output IRQ signal goes active (LOW). If  
the AL1E bit is not set, the AL1 bit is set, but the IRQ  
signal remains unchanged.  
Block Protect Bits—BP2, BP1, BP0 (Nonvolatile)  
The Block Protect Bits, BP2, BP1 and BP0, determine  
which blocks of the array are write protected. A write to  
a protected block of memory is ignored. The block pro-  
tect bits will prevent write operations to one of eight  
segments of the array. The partitions are described in  
Table 3.  
Reading the status register, containing the AL0 and  
AL1 bits, resets the bits. The bits do not reset until the  
falling edge of the 8th output clock of the status register  
containing the Alarm bits. When the bits reset, the out-  
put IRQ signal returns to the inactive state.  
Table 3. Block Protect Bits  
Protected Addresses  
Pulsed Interrupt Mode (IM Bit = 1)  
X1243  
Array Lock  
None  
In this mode, the alarm interrupt enable bits (AL0E and  
AL1E) are not used. Alarm 1 operates as before, so a  
match of the RTC and Alarm 1 sets the AL1 bit. Since  
the interrupt enable bits have no function, it is neces-  
sary for the host processor to poll the AL1 bit to deter-  
mine if an alarm has occurred.  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
None  
600 - 7FF  
h
Upper 1/4  
Upper 1/2  
Full Array  
First Page  
First 2 pgs  
First 4 pgs  
First 8 pgs  
h
h
h
400 - 7FF  
h
000 - 7FF  
h
000 - 03F  
h
h
h
Alarm 0 provides an output response. In this case,  
when the RTC matches the Alarm 0 registers, the out-  
put IRQ pulses one time. This pulse can be used to  
control some outside circuit or event, without the need  
for a local processor. The duration of the pulse is 1024  
cycles of the 32.748kHz oscillator. All alarm 0 enable  
options are available, so this becomes a very flexible  
long term repeat trigger.  
000 - 07F  
h
000 - 0FF  
h
h
h
000 - 1FF  
h
Interrupt Control Bits (AL1E, AL0E)  
There are two Interrupt Control bits, Alarm 1 Interrupt  
Enable (AL1E) and Alarm 0 Interrupt Enable (AL0E) to  
specifically enable or disable the alarm interrupt signal  
output. The interrupt output is enabled when either bit is  
set to ‘1’. Two volatile bits (AL1 and AL0), associated  
with these alarms, indicate if an alarm has happened.  
These bits are set on an alarm condition regardless of  
whether the alarm interrupts are enabled. The AL1 and  
AL0 bits are reset by the falling edge of the 8th clock of  
a read of the register containing the bits.  
WRITING TO THE CLOCK/CONTROL REGISTERS  
Changing any of the nonvolatile bits of the clock/control  
register requires the following steps:  
– Write a 02H to the Status Register to set the Write  
Enable Latch (WEL). This is a volatile operation, so  
there is no delay after the write. (Operation pre-  
ceeded by a start and ended with a stop).  
– Write a 06H to the Status Register to set both the  
Register Write Enable Latch (RWEL) and the WEL  
bit. This is also a volatile cycle. The zeros in the data  
byte are required. (Operation preceeded by a start  
and ended with a stop).  
In an alternative mode (called pulsed interrupt mode),  
controlled by an interrupt mode (IM) bit, the alarm 0  
setting provides an output pulse on IRQ each time the  
alarm matches the RTC. In this case the AL0 bit is not  
used. Alarm 1 works as before (i.e. the AL1 bit is set  
when an alarm occurs), but it is necessary to poll the sta-  
tus register to determine whether a match has occurred.  
This read operation is necessary to reset the AL1 flag.  
– Write one to 8 bytes to the Clock/Control Registers  
with the desired clock, alarm, or control data. This  
sequence starts with a start bit, requires a slave byte  
of “11011110” and an address within the CCR and is  
terminated by a stop bit. A write to the CCR changes  
EEPROM values so these initiate a nonvolatile write  
cycle and will take up to 10ms to complete. Writes to  
undefined areas have no effect. The RWEL bit is  
reset by the completion of a nonvolatile write write  
cycle, so the sequence must be repeated to again  
Normal Mode (IM Bit = 0)  
A match of the RTC and the contents of the alarm 0  
registers automatically sets the AL0 bit. If the AL0E bit  
is also set, the output IRQ signal goes active (LOW). If  
the AL0E bit is not set, the AL0 bit is set, but the IRQ  
signal remains unchanged.  
Characteristics subject to change without notice. 6 of 18  