X1243 – Preliminary Information  
initiate another change to the CCR contents. If the  
sequence is not completed for any reason (by send-  
ing an incorrect number of bits or sending a start  
instead of a stop, for example) the RWEL bit is not  
reset and the device remains in an active mode.  
SERIAL COMMUNICATION  
Interface Conventions  
The device supports a bidirectional bus oriented proto-  
col. The protocol defines any device that sends data  
onto the bus as a transmitter, and the receiving device  
as the receiver. The device controlling the transfer is  
called the master and the device being controlled is  
called the slave. The master always initiates data  
transfers, and provides the clock for both transmit and  
receive operations. Therefore, the devices in this family  
operate as slaves in all applications.  
– Writing all zeros to the status register resets both the  
WEL and RWEL bits.  
– A read operation occurring between any of the previ-  
ous operations will not interrupt the register write  
operation.  
– The RWEL and WEL bits can be reset by writing a 0  
to the Status Register.  
Figure 3. Valid Data Changes on the SDA Bus  
SCL  
SDA  
Data Stable  
Data Change  
Data Stable  
Clock and Data  
SCL lines for the start condition and will not respond to  
any command until this condition has been met. See  
Figure 4.  
Data states on the SDA line can change only during  
SCL LOW. SDA state changes during SCL HIGH are  
reserved for indicating start and stop conditions. See  
Figure 3.  
Stop Condition  
All communications must be terminated by a stop con-  
dition, which is a LOW to HIGH transition of SDA when  
SCL is HIGH. The stop condition is also used to place  
the device into the Standby power mode after a read  
sequence. A stop condition can only be issued after  
the transmitting device has released the bus Refer to  
Figure 4.  
Start Condition  
All commands are preceded by the start condition,  
which is a HIGH to LOW transition of SDA when SCL is  
HIGH. The device continuously monitors the SDA and  
Figure 4. Valid Start and Stop Conditions  
SCL  
SDA  
Start  
Stop  
Characteristics subject to change without notice. 7 of 18  
REV 1.1.4 5/31/01  