VSC7216-02
Data Sheet
Recommended Operating Conditions
Table 21. Recommended Operating Conditions
Symbol Parameter
Min
2.375
0
Typ
Max
2.625
100
Unit
V
Condition
VDD
T
Power Supply Voltage
Operating Temperature Range
2.5
°C
1. Lower limit of specification is ambient temperature, and upper limit is case temperature.
Absolute Maximum Ratings
Table 22. Absolute Maximum Ratings
Symbol Parameter
Min
–0.5
–0.5
–0.5
–0.5
–0.5
Max
2.9
Unit
V
Condition
VDDx
VDDT
Power Supply Voltage (any VDDx except VDDT
Power Supply Voltage
)
3.8
V
Input Voltage, PECL
VDD + 0.5
5.5
V
Input Voltage, TTL
V
Output Voltage, TTL
VDD + 0.5
50
V
Output Current, TTL
mA
mA
°C
°C
V
Output Current, PECL
50
TC
Case Temperature Under Bias
Storage Temperature
–55
–65
125
TS
150
VESD
Electrostatic Discharge (human body model)
–1200
1200
Stresses listed under Absolute Maximum Ratings may be applied to devices one at a time without causing permanent damage. Functionality at or above the values
listed is not implied. Exposure to these values for extended periods may affect device reliability.
ELECTROSTATIC DISCHARGE
This device can be damaged by ESD. Vitesse recommends that all integrated circuits
be handled with appropriate precautions. Failure to observe proper handling and
installation procedures may adversely affect reliability of the device.
29 of 40
G52367 Revision 4.2
December 2006