34 / 102
TMC4670 Datasheet PRELIMINARY • IC Version V0.99 | Document Revision V0.91 • 2016-Nov-09
Address
Registername
Access
1: UX = ADC_I1
2: UX = ADC_I2
Mask
Name
Type
0x0C000000h
ADC_I_V_SELECT
Choice
Unit
Min
0
Max
2
Default
0
0: V = ADC_I0
1: V = ADC_I1 (default)
2: V = ADC_I2
Name
Mask
Type
0x30000000h
ADC_I_WY_SELECT
Max
Choice
Unit
Min
Default
0
0
2
0: WY = ADC_I0
1: WY = ADC_I1
2: WY = ADC_I2 (default)
AENC_0_SCALE_OFFSET
0x0Dh
RW
Mask
Name
AENC_0_OFFSET
Max
Type
Signed
Unit
0x0000FFFFh
Min
Default
0
-32768
32767
Offset for Analog Encoder ADC channel 0.
Mask
Name
Type
Signed
Unit
0xFFFF0000h
AENC_0_SCALE
Min
Max
Default
0
-32768
32767
Scaling factor for Analog Encoder ADC channel 0.
AENC_1_SCALE_OFFSET
0x0Eh
RW
Mask
Name
AENC_1_OFFSET
Max
Type
Signed
Unit
0x0000FFFFh
Min
Default
0
-32768
32767
Offset for Analog Encoder ADC channel 1.
Mask
Name
Type
0xFFFF0000h
AENC_1_SCALE
Signed
©2016 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com
Read entire documentation.