33 / 102
TMC4670 Datasheet PRELIMINARY • IC Version V0.99 | Document Revision V0.91 • 2016-Nov-09
Address
0x0Ah
Registername
Max
Access
Min
Default
0
Unit
-32768
32767
Scaling factor for current ADC channel 0.
ADC_I_SELECT
Name
RW
Mask
Type
0x000000FFh
ADC_I0_SELECT
Choice
Unit
Min
0
Max
7
Default
0
Select input for raw current ADC_I0_RAW.
0: ADC_I0_RAW (analog input ADC_I_U)
1: ADC_I1_RAW (analog input ADC_I_V)
2: ADC_I0_EXT (from register)
3: ADC_I1_EXT (from register)
4: ADCSD_I0_RAW (sigma delta ADC)
5: ADCSD_I1_RAW (sigma delta ADC)
6: ADCSPI_I0_RAW (SPI ADC_I_UX)
7: ADCSPI_I1_RAW (SPI ADC_I_WY)
Name
Mask
Type
0x0000FF00h
ADC_I1_SELECT
Choice
Unit
Min
0
Max
7
Default
0
Select input for raw current ADC_I1_RAW.
0: ADC_I0_RAW (analog input ADC_I_U)
1: ADC_I1_RAW (analog input ADC_I_V)
2: ADC_I0_EXT (from register)
3: ADC_I1_EXT (from register)
4: ADCSD_I0_RAW (sigma delta ADC)
5: ADCSD_I1_RAW (sigma delta ADC)
6: ADCSPI_I0_RAW (SPI ADC_I_UX)
7: ADCSPI_I1_RAW (SPI ADC_I_WY)
Name
Mask
Type
0x03000000h
ADC_I_UX_SELECT
Choice
Unit
Min
0
Max
2
Default
0
0: UX = ADC_I0 (default)
©2016 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com
Read entire documentation.