TPS929160-Q1
ZHCSNG0 – APRIL 2023
www.ti.com.cn
表 7-103. DIAGEN1 Register Field Descriptions (continued)
Bit
Field
DIAGENOUTC0
Type
Reset
Description
0
R/W
X
Diagnostics enable register for OUTC0
Load EEPROM data when reset
0h = Disabled
1h = Enabled
7.6.3.3 DIAGEN2 Register (Offset = 72h) [Reset = X]
DIAGEN2 is shown in 图 7-100 and described in 表 7-104.
Return to the Summary Table.
图 7-100. DIAGEN2 Register
7
6
5
4
3
2
1
0
RESERVED
R-0h
DIAGENOUTF1 DIAGENOUTF0
R/W-X R/W-X
RESERVED
R-0h
DIAGENOUTE1 DIAGENOUTE0
R/W-X R/W-X
表 7-104. DIAGEN2 Register Field Descriptions
Bit
Field
Type
Reset
Description
7-6
5
RESERVED
R
0h
Reserved
DIAGENOUTF1
R/W
X
Diagnostics enable register for OUTF1
Load EEPROM data when reset
0h = Disabled
1h = Enabled
4
DIAGENOUTF0
R/W
X
Diagnostics enable register for OUTF0
Load EEPROM data when reset
0h = Disabled
1h = Enabled
3-2
1
RESERVED
R
0h
X
Reserved
DIAGENOUTE1
R/W
Diagnostics enable register for OUTE1
Load EEPROM data when reset
0h = Disabled
1h = Enabled
0
DIAGENOUTE0
R/W
X
Diagnostics enable register for OUTE0
Load EEPROM data when reset
0h = Disabled
1h = Enabled
7.6.3.4 DIAGEN3 Register (Offset = 73h) [Reset = X]
DIAGEN3 is shown in 图 7-101 and described in 表 7-105.
Return to the Summary Table.
图 7-101. DIAGEN3 Register
7
6
5
4
3
2
1
0
RESERVED
R-0h
DIAGENOUTH1 DIAGENOUTH0
RESERVED
R-0h
DIAGENOUTG DIAGENOUTG
1
0
R/W-X R/W-X
R/W-X
R/W-X
表 7-105. DIAGEN3 Register Field Descriptions
Bit
7-6
Field
Type
Reset
Description
RESERVED
R
0h
Reserved
Copyright © 2023 Texas Instruments Incorporated
Submit Document Feedback
89
Product Folder Links: TPS929160-Q1
English Data Sheet: SLVSG60