www.ti.com ................................................................................................................................................. SBVS120AJULY 2008REVISED SEPTEMBER 2008  
DETAILED DESCRIPTION  
SETTING FOR THE CONSTANT SINK CURRENT VALUE  
The constant current values are determined by an external resistor (RIREF) placed between IREF and GND. The  
resistor (RIREF) value is calculated by Equation 1.  
VIREF (V)  
RIREF (kW) =  
´ 42  
IOLC (mA)  
(1)  
Where:  
VIREF = the internal reference voltage on the IREF pin (typically 1.20 V)  
IOLC must be set in the range of 2 mA to 35 mA. The constant sink current characteristic for the external resistor  
value is shown in Figure 10. Table 1 describes the constant current output versus external resistor value.  
Table 1. Constant Current Output versus External Resistor Value  
IOLCMax (mA, Typical)  
RIREF (k)  
1.44  
35  
30  
25  
20  
15  
10  
5
1.68  
2.02  
2.52  
3.36  
5.04  
10.1  
2
25.2  
CONSTANT CURRENT DRIVER ON/OFF CONTROL  
When BLANK is low, the corresponding output is turned on if the data in the on/off control data latch are '1' and  
remains off if the data are '0'. When BLANK is high, all outputs are forced off. This control is shown in Table 2.  
Table 2. On/Off Control Data Truth Table  
ON/OFF CONTROL LATCH DATA  
CONSTANT CURRENT OUTPUT STATUS  
0
1
Off  
On  
When the IC is initially powered on, the data in the on/off control shift register and data latch are not set to the  
respective default value. Therefore, the on/off control data must be written to the data latch before turning the  
constant current output on. BLANK should be at a high level when powered on because the constant current  
may be turned on as a result of random data in the on/off control latch.  
The on/off data corresponding to any unconnected OUTn outputs should be set to ‘0’ before turning on the  
remaining outputs. Otherwise, the supply current (ICC) increases while the LEDs are on.  