ADS131B04-Q1  
ZHCSMK3B NOVEMBER 2020 REVISED NOVEMBER 2021  
www.ti.com.cn  
CS  
SCLK  
DIN  
RESET  
CRC  
RESET command  
latched here  
DOUT  
Hi-Z  
Response  
Don‘t Care  
Don‘t Care  
Don‘t Care  
Don‘t Care  
Don‘t Care  
Hi-Z  
8-20. RESET Command Frame  
8.5.3.3 STANDBY (0000 0000 0010 0010)  
The STANDBY command places the device in a low-power standby mode. The command is latched by the  
device at the end of the frame. The device enters standby mode immediately after the command is latched. See  
the Standby Mode section for more information. This command has no effect when the device is already in  
standby mode.  
8.5.3.4 WAKEUP (0000 0000 0011 0011)  
The WAKEUP command returns the device to conversion mode from standby mode. This command has no  
effect if the device is already in conversion mode.  
8.5.3.5 LOCK (0000 0101 0101 0101)  
The LOCK command locks the interface, preventing the device from accidentally latching unwanted commands  
that can change the state of the device. When the interface is locked, the device only responds to the NULL,  
RREG, and UNLOCK commands. The device continues to output conversion data even when locked.  
8.5.3.6 UNLOCK (0000 0110 0110 0110)  
The UNLOCK command unlocks the interface if previously locked by the LOCK command.  
8.5.3.7 RREG (101a aaaa annn nnnn)  
The RREG is used to read the device registers. The binary format of the command word is 101a aaaa annn  
nnnn, where a aaaa a is the binary address of the register to begin reading and nnn nnnn is the unsigned binary  
number of consecutive registers to read minus one. There are two cases for reading registers on the  
ADS131B04-Q1. When reading a single register (nnn nnnn = 000 0000b), the device outputs the register  
contents in the command response word of the following frame. If multiple registers are read using a single  
command (nnn nnnn > 000 0000b), the device outputs the requested register data sequentially in order of  