Three Port 10/100 Managed Ethernet Switch with MII  
Datasheet  
LAN9313/LAN9313i, the master may either send data bytes to be written, or it may send another start  
condition (to start the reading of data), or a stop condition. The latter two will terminate the current  
write (without writing any data), but will have the affect of setting the internal register address which  
will be used for subsequent reads.  
If the read/write indication in the control byte is a 1 (indicating a read), the LAN9313/LAN9313i will  
start sending data following the control byte acknowledgement.  
Note: All registers are accessed as DWORDs. Appending two 0 bits to the address field will form the  
register address. Addresses and data are transferred msb first. Data is transferred MSB first  
(little endian).  
Control Byte  
Address Byte  
S
A
6
S
A
5
S
A
4
S
A
3
S
A
2
S
A
1
S
A
0
A
C
K
A
C
K
A
9
A
8
A
7
A
6
A
5
A
4
A
3
A
2
S
0
*
Start or  
Stop or  
Data [31]  
R/~W  
Figure 8.3 I2C Slave Addressing  
2
8.5.2  
I C Slave Read Sequence  
Following the device addressing, as detailed in Section 8.5.1, a register is read from the  
LAN9313/LAN9313i when the master sends a start condition and control byte with the R/~W bit set.  
Assuming the slave address in the control byte matches the LAN9313/LAN9313i address, the control  
byte is acknowledged by the LAN9313/LAN9313i. Otherwise, the entire sequence is ignored until the  
next start condition. Following the acknowledge, the LAN9313/LAN9313i sends 4 bytes of data. The  
first 3 bytes are acknowledged by the master and on the fourth, the master sends a no-acknowledge  
followed by the stop condition. The no-acknowledge informs the LAN9313/LAN9313i not to send the  
next 4 bytes (as it would in the case of a multiple read). The internal register address is unchanged  
following the single read.  
Multiple reads are performed when the master sends an acknowledge on the fourth byte. The internal  
address is incremented and the next register is shifted out. Once the internal address reaches its  
maximum, it rolls over to 0. The multiple read is concluded when the master sends a no-acknowledge  
followed by a stop condition. The no-acknowledge informs the LAN9313/LAN9313i not to send the next  
4 bytes. The internal register address in incremented for each read including the final.  
For both single and multiple reads, in the case that the master sends a no-acknowledge on any of the  
first three bytes of the register, the LAN9313/LAN9313i will stop sending subsequent bytes. If the  
master sends an unexpected start or stop condition, the LAN9313/LAN9313i will stop sending  
immediately and will respond to the next sequence as needed.  
Since data is read serially, register values are latched (registered) at the beginning of each 32-bit read  
to prevent the host from reading an intermediate value. The latching occurs multiple times in a multiple  
read sequence. In addition, any register that is affected by a read operation (e.g. a clear on read bit)  
is not cleared until after all 32-bits are output. In the event that 32-bits are not read (master sends a  
no-acknowledge on one of the first three bytes or a start or stop condition occurs unexpectedly), the  
read is considered invalid and the register is not affected. Multiple registers may be cleared in a  
2
multiple read cycle, each one being cleared as it is read. I C reads from unused register addresses  
return all zeros.  
Revision 1.2 (04-08-08)  
122  
SMSC LAN9313/LAN9313i  
DATASHEET  