Data Rate Select, Bits 0 - 1  
These bits determine the data rate of the floppy controller. See Table 22 for the appropriate values.  
No Precompensation, Bit 2  
This bit can be set by software, but it has no functionality. It can be read by bit 2 of the DSR when in Model 30  
register mode. Unaffected by software reset.  
RESERVED, Bits 3 - 7  
Bits 3 to 7 are RESERVED. Reserved bits cannot be written and return 0 when read.  
Status Register Encoding  
During the Result Phase of certain commands, the Data Register contains data bytes that give the status of the  
command just executed.  
.
Table 31 - Status Register 0  
BIT  
NO.  
7,6  
SYMBOL  
IC  
NAME  
Interrupt  
Code  
DESCRIPTION  
00 - Normal termination of command. The specified command was properly  
executed and completed without error.  
01 - Abnormal termination of command. Command execution was started,  
but was not successfully completed.  
10 - Invalid command. The requested command could not be executed.  
11 - Abnormal termination caused by Polling.  
5
4
SE  
EC  
Seek End  
The FDC completed a Seek, Relative Seek or Recalibrate command (used  
during a Sense Interrupt Command).  
Equipment The TRK0 pin failed to become a “1” after:  
Check  
1. 80 step pulses in the Recalibrate command.  
2. The Relative Seek command caused the FDC to step outward beyond  
Track 0.  
3
2
Unused. This bit is always “0”.  
The current head address.  
H
Head  
Address  
1,0  
DS1,0  
Drive  
The current selected drive.  
Select  
Table 32 - Status Register 1  
BIT  
NO.  
7
SYMBOL  
EN  
NAME  
End of  
Cylinder  
DESCRIPTION  
The FDC tried to access a sector beyond the final sector of the track (255D).  
Will be set if TC is not issued after Read or Write Data command.  
Unused. This bit is always “0”.  
6
5
DE  
OR  
Data Error The FDC detected a CRC error in either the ID field or the data field of a  
sector.  
Overrun/  
Underrun  
4
Becomes set if the FDC does not receive CPU or DMA service within the  
required time interval, resulting in data overrun or underrun.  
Unused. This bit is always “0”.  
3
2
ND  
No Data  
Any one of the following:  
1. Read Data, Read Deleted Data command - the FDC did not find the  
specified sector.  
2. Read ID command - the FDC cannot read the ID field without an error.  
3. Read A Track command - the FDC cannot find the proper sector  
sequence.  
1
NW  
Not  
Writable  
WP pin became a “1” while the FDC is executing a Write Data, Write Deleted  
Data, or Format A Track command.  
SMSC DS – FDC37N769  