欢迎访问ic37.com |
会员登录 免费注册
发布采购

FDC37N769_07 参数 Datasheet PDF下载

FDC37N769_07图片预览
型号: FDC37N769_07
PDF下载: 下载PDF文件 查看货源
内容描述: 3.3V超级I / O控制器具有红外支持针对便携式应用 [3.3V Super I/O Controller with Infrared Support for Portable Applications]
分类和应用: 控制器便携式
文件页数/大小: 137 页 / 659 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号FDC37N769_07的Datasheet PDF文件第28页浏览型号FDC37N769_07的Datasheet PDF文件第29页浏览型号FDC37N769_07的Datasheet PDF文件第30页浏览型号FDC37N769_07的Datasheet PDF文件第31页浏览型号FDC37N769_07的Datasheet PDF文件第33页浏览型号FDC37N769_07的Datasheet PDF文件第34页浏览型号FDC37N769_07的Datasheet PDF文件第35页浏览型号FDC37N769_07的Datasheet PDF文件第36页  
the command unless an illegal command condition is detected. After the last parameter byte is received, RQM  
remains “0” and the FDC automatically enters the next phase as defined by the command definition.  
The FIFO is disabled during the command phase to provide for the proper handling of the “Invalid Command”  
condition.  
Execution Phase  
All data transfers to or from the FDC occur during the execution phase, which can proceed in DMA or non-DMA mode  
as indicated in the Specify command.  
After a reset, the FIFO is disabled. Each data byte is transferred by an FINT or FDRQ depending on the DMA mode.  
The Configure command can enable the FIFO and set the FIFO threshold value.  
The following paragraphs detail the operation of the FIFO flow control. In these descriptions, <threshold> is defined  
as the number of bytes available to the FDC when service is requested from the host and ranges from 1 to 16. The  
parameter FIFOTHR, which the user programs, is one less and ranges from 0 to 15.  
A low threshold value (i.e. 2) results in longer periods of time between service requests, but requires faster servicing  
of the request for both read and write cases. The host reads (writes) from (to) the FIFO until empty (full), then the  
transfer request goes inactive. The host must be very responsive to the service request. This is the desired case for  
use with a “fast” system.A high value of threshold (i.e. 12) is used with a “sluggish” system by affording a long latency  
period after a service request, but results in more frequent service requests.  
Non-DMA Mode Transfers  
FIFO to Host  
The FINT pin and RQM bits in the Main Status Register are activated when the FIFO contains (16-<threshold>) bytes  
or the last bytes of a full sector have been placed in the FIFO. The FINT pin can be used for interrupt-driven  
systems, and RQM can be used for polled systems. The host must respond to the request by reading data from the  
FIFO. This process is repeated until the last byte is transferred out of the FIFO. The FDC will deactivate the FINT  
pin and RQM bit when the FIFO becomes empty.  
Host to FIFO  
The FINT pin and RQM bit in the Main Status Register are activated upon entering the execution phase of data  
transfer commands. The host must respond to the request by writing data into the FIFO. The FINT pin and RQM bit  
remain true until the FIFO becomes full. They are set true again when the FIFO has <threshold> bytes remaining in  
the FIFO. The FINT pin will also be deactivated if TC and nDACK both go inactive. The FDC enters the result phase  
after the last byte is taken by the FDC from the FIFO (i.e. FIFO empty condition).  
DMA Mode Transfers  
FIFO to Host  
The FDC activates the DDRQ pin when the FIFO contains (16 - <threshold>) bytes, or the last byte of a full sector  
transfer has been placed in the FIFO. The DMA controller must respond to the request by reading data from the  
FIFO. The FDC will deactivate the DDRQ pin when the FIFO becomes empty. FDRQ goes inactive after nDACK  
goes active for the last byte of a data transfer (or on the active edge of nIOR, on the last byte, if no edge is present  
on nDACK). A data underrun may occur if FDRQ is not removed in time to prevent an unwanted cycle.  
Host to FIFO  
The FDC activates the FDRQ pin when entering the execution phase of the data transfer commands. The DMA  
controller must respond by activating the nDACK and nIOW pins and placing data in the FIFO. FDRQ remains active  
until the FIFO becomes full. FDRQ is again set true when the FIFO has <threshold> bytes remaining in the FIFO.  
The FDC will also deactivate the FDRQ pin when TC becomes true (qualified by nDACK), indicating that no more  
data is required. FDRQ goes inactive after nDACK goes active for the last byte of a data transfer (or on the active  
edge of nIOW of the last byte, if no edge is present on nDACK). A data overrun may occur if FDRQ is not removed in  
time to prevent an unwanted cycle.  
SMSC DS – FDC37N769  
Page 32 of 137  
Rev. 02-16-07  
DATASHEET  
 复制成功!