Fan Control Device with Hardware Monitoring and Acoustic Noise Reduction Features  
Datasheet  
Table 7.14 Temperature Limit vs. Register Setting  
LIMIT  
LIMIT (DEC)  
LIMIT (HEX)  
-127°c  
-127  
81h  
.
.
.
.
.
.
.
.
.
-50°c  
-50  
CEh  
.
.
.
.
.
.
.
.
.
0°c  
0
00h  
.
.
.
.
.
.
.
.
.
50°c  
50  
32h  
.
.
.
.
.
.
.
.
.
127°c  
127  
7Fh  
7.2.21  
Registers 6A-6Ch: Absolute Temperature Limit  
Register  
Address  
Read/  
Write  
Bit 7  
Bit 0  
Default  
Value  
Register Name  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
(MSb)  
(LSb)  
6Ah  
6Bh  
6Ch  
R/W  
R/W  
R/W  
Zone 1 Temp Absolute Limit  
Zone 2 Temp Absolute Limit  
Zone 3 Temp Absolute Limit  
7
7
7
6
6
6
5
5
5
4
4
4
3
3
3
2
2
2
1
1
1
0
0
0
64h  
64h  
64h  
These registers become read only when the Lock bit is set. Any further attempts to write to these  
registers shall have no effect.  
In Auto Fan mode, if any zone associated with a PWM output exceeds the temperature set in the  
Absolute limit register, all PWM outputs will increase their duty cycle to 100% except those that are  
disabled via the PWM Configuration registers. This is a safety feature that attempts to cool the system  
if there is a potentially catastrophic thermal event.  
If an absolute limit register set to 80h (-128°c), the safety feature is disabled for the associated zone.  
That is, if 80h is written into the Zone x Temp Absolute Limit Register, then regardless of the reading  
register for the zone, the fans will not turn on-full based on the absolute temp condition.  
Default =100°c=64h.  
When any fan is in auto fan mode, then if the temperature in any zone exceeds absolute limit, all fans  
go to full, including any in manual mode, except those that are disabled. Therefore, even if a zone is  
not associated with a fan, if that zone exceeds absolute, then all fans go to full. In this case, the  
absolute limit can be chosen to be 7Fh for those zones that are not associated with a fan, so that the  
fans won't turn on unless the temperature hits 127 degrees.  
SMSC EMC6D102  
Revision 0.4 (04-05-05)  