PM7385 FREEDM-84A672  
DATA SHEET  
PMC-1990114  
ISSUE 6  
84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER  
WITH ANY-PHY PACKET INTERFACE  
a mismatch between the received FCS code and the computed CRC residue  
will cause the PMON Configurable Accumulator #1 register to increment.  
Receive frame check sequence errors are ignored when RFCSE1EN is set  
low.  
RABRT1EN:  
The receive abort accumulate enable bit (RABRT1EN) enables counting of  
receive HDLC abort events. When RABRT1EN is set high, receipt of an abort  
code (at least 7 contiguous 1’s) will cause the PMON Configurable  
Accumulator #1 register to increment. Receive aborts are ignored when  
RABRT1EN is set low.  
RLENE1EN:  
The receive packet length error accumulate enable bit (RLENE1EN) enables  
counting of receive packet length error events. When RLENE1EN is set high,  
receipt of a packet that is longer than the programmable maximum or of a  
packet that in not octet aligned will cause the PMON Configurable  
Accumulator #1 register to increment. (Receipt of a packet that is both too  
long and not octet aligned results in only one increment.) Receive packet  
length errors are ignored when RLENE1EN is set low.  
RP1EN:  
The receive packet enable bit (RP1EN) enables counting of receive error-free  
packets. When RP1EN is set high, receipt of an error-free packet will cause  
the PMON Configurable Accumulator #1 register to increment. Receive error-  
free packets are ignored when RP1EN is set low.  
TABRT1EN:  
The transmit abort accumulate enable bit (TABRT1EN) enables counting of  
transmit HDLC abort events. When TABRT1EN is set high, insertion of an  
abort in the outgoing stream will cause the PMON Configurable Accumulator  
#1 register to increment. Transmit aborts are ignored when TABRT1EN is set  
low.  
TP1EN:  
The transmit packet enable bit (TP1EN) enables counting of transmit  
error-free packets. When TP1EN is set high, transmission of an error-free  
packet will cause the PMON Configurable Accumulator #1 register to  
increment. Transmit error-free packets are ignored when TP1EN is set low.  