PM7385 FREEDM-84A672  
DATA SHEET  
PMC-1990114  
ISSUE 6  
84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER  
WITH ANY-PHY PACKET INTERFACE  
RSPE2EN:  
The receive small packet error accumulate enable bit (RSPE2EN) enables  
counting of minimum packet size violation events. When RSPE2EN is set  
high, receipt of a packet that is shorter than 32 bits (CRC-CCITT, Unspecified  
CRC or no CRC) or 48 bits (CRC-32) will cause the PMON Configurable  
Accumulator #2 register to increment. Small packet errors are ignored when  
RSPE2EN is set low.  
RFCSE2EN:  
The receive frame check sequence error accumulate enable bit (RFCSE2EN)  
enables counting of receive FCS error events. When RFCSE2EN is set high,  
a mismatch between the received FCS code and the computed CRC residue  
will cause the PMON Configurable Accumulator #2 register to increment.  
Receive frame check sequence errors are ignored when RFCSE2EN is set  
low.  
RABRT2EN:  
The receive abort accumulate enable bit (RABRT2EN) enables counting of  
receive HDLC abort events. When RABRT2EN is set high, receipt of an abort  
code (at least 7 contiguous 2’s) will cause the PMON Configurable  
Accumulator #2 register to increment. Receive aborts are ignored when  
RABRT2EN is set low.  
RLENE2EN:  
The receive packet length error accumulate enable bit (RLENE2EN) enables  
counting of receive packet length error events. When RLENE2EN is set high,  
receipt of a packet that is longer than the programmable maximum or of a  
packet that in not octet aligned will cause the PMON Configurable  
Accumulator #2 register to increment. (Receipt of a packet that is both too  
long and not octet aligned results in only one increment.) Receive packet  
length errors are ignored when RLENE2EN is set low.  
RP2EN:  
The receive packet enable bit (RP2EN) enables counting of receive error-free  
packets. When RP2EN is set high, receipt of an error-free packet will cause  
the PMON Configurable Accumulator #2 register to increment. Receive error-  
free packets are ignored when RP2EN is set low.  
TABRT2EN:  
The transmit abort accumulate enable bit (TABRT2EN) enables counting of  
transmit HDLC abort events. When TABRT2EN is set high, insertion of an  
abort in the outgoing stream will cause the PMON Configurable Accumulator  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
78  