S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Pin Name  
OCIF_ENB_STPA  
Type  
Input  
Pin No Function  
(A) RPU_RDENB  
(A) Active-Low Read enable. When RPU_RDENB is asserted, a  
read is executed from the S/UNI-ATLAS-3200 on the PHYID  
which was present on RPU_ADDR during the cycle before  
RPU_RDENB was asserted.  
(B) not used  
(C) RPP_ENB  
(C) Active-Low Read enable. The RPP_ENB signal is used to  
backpressure the flow of data from the receive FIFOs. During  
data transfer, RPP_VAL must be monitored as it will indicate if  
the RPP_DAT[31:0], RPP_MOD[1:0], RPP_SOP, RPP_EOP,  
RPP_ERR and RPP_SX are valid. The system may deassert  
RPP_ENB at anytime if it is unable to accept data from the  
S/UNI-ATLAS-3200.  
When RPP_ENB is sampled low, a read is performed from the  
receive FIFO and the RPP_DAT[31:0], RPP_PAR,  
RPP_MOD[1:0], RPP_SOP, RPP_EOP, RPP_ERR, RPP_SX  
and RPP_VAL signals are updated on the following rising edge of  
RPP_CLK.  
When RPP_ENB is sampled low by the PHY device, a read is not  
performed and the RPP_DAT[31:0], RPP_PAR, RPP_MOD[1:0],  
RPP_SOP, RPP_EOP, RPP_ERR, RPP_SX and RPP_VAL  
signals will not updated on the following rising edge of RPP_CLK.  
(D) TLP_STPA  
(D) Selected PHY packet available.  
TLP_STPA always provides status indication for the selected port  
of PHY device in order to avoid FIFO overflows while polling is  
performed. The use of TLP_STPA is optional. If USE_STPA is  
logic 0 in the TxLink Configuration Register, then TLP_STPA is  
ignored. If USE_STPA is logic 1, then the S/UNI-ATLAS-3200  
will cease transmission immediately after sampling TLP_STPA  
high, and may switch to another PHY at that point.  
The port which TLP_STPA reports is updated on the following  
rising edge of TLP_CLK after the PHY address on TLP_DAT is  
sampled by the PHY device.  
OCIF_SX  
Output  
(A) not used  
(B) not used  
(C) RPP_SX  
(C) Start of transfer. RPP_SX indicates when the in-band port  
address is present on the RPP_DAT bus. When RPP_SX is high  
and RPP_VAL is low, the value of RPP_DAT[7:0] is the address  
of the receive FIFO to be selected by the PHY. Subsequent data  
transfers on the RDAT bus will be from the FIFO specified by this  
in-band address.  
RPP_SX will not be asserted at the same time as RPP_VAL.  
(D) TLP_SX  
(D) Start of transfer. TLP_SX indicates when the in-band port  
address is present on the TLP_DAT bus. When TLP_SX is high  
and TLP_ENB is high, the value of TLP_DAT[7:0] is the address  
of the transmit FIFO to be selected. Subsequent data transfers  
on the TLP_DAT bus will fill the FIFO specified by this in-band  
address.  
TLP_SX will not be asserted at the same time as TLP_ENB  