ISP1362  
Single-chip USB OTG controller  
Philips Semiconductors  
Table 69: HcµPInterrupt register: bit description  
Bit  
Symbol  
-
Description  
reserved  
15 to 10  
9
OTG_IRQ  
0 no event  
1 The OTG interrupt event needs to read the OtgInterrupt  
register to get the cause of the interrupt.  
8
7
ATL_IRQ  
0 no event  
1 Count value of the HcATLDoneThresholdCount register or the  
time-out value of the HcATLPTDDoneThresholdTimeOut register  
has reached. The microprocessor is required to read  
HcINTLPTDDoneMap to check the PTDs that have completed  
their transactions.  
INTL_IRQ 0 no event  
1 The HC has detected the last PTD, and there is at least one  
interrupt transaction that has received ACK from the device. The  
microprocessor is required to read HcINTLPTDDoneMap to check  
the PTDs that have received ACK from the device.  
6
5
ClkReady  
0 no event  
1 The HC has awakened from the suspendstate, and its  
internal clock has turned on again.  
HC  
0 no event  
Suspended  
1 The HC has been suspended and no USB activities are sent  
from the microprocessor for each ms. The microprocessor can  
suspend the HC by setting bits 6 and 7 of the HcControl register to  
logic 1. Once the HC is suspended, no SOF needs to be sent to  
the devices connected to downstream ports.  
4
3
OPR_Reg 0 no event  
1 An HC operation has caused a hardware interrupt. It is  
necessary for the HCD to read the HcInterruptStatus register to  
determine the cause of the interrupt.  
AllEOT  
0 no event  
Interrupt  
1 Data transfer has been completed by using the PIO transfer or  
the DMA transfer. This bit is set either when the value of the  
HcTransferCounter register has reached zero, or the EOT pin of  
the HC is triggered by an external signal.  