< Dual-In-Line Package Intelligent Power Module >
PSS20S92F6-AG, PSS20S92E6-AG
TRANSFER MOLDING TYPE
INSULATED TYPE
MECHANICAL CHARACTERISTICS AND RATINGS
Limits
Typ.
Parameter
Mounting torque
Condition
Unit
Min.
0.59
Max.
0.78
Mounting screw : M3 (Note 8)
Recommended 0.69N·m
EIAJ-ED-4701
0.69
N·m
s
Control terminal: Load 4.9N
Power terminal: Load 9.8N
Control terminal: Load 2.45N
Power terminal: Load 4.9N
90deg. bend
Terminal pulling strength
10
-
-
Terminal bending strength
EIAJ-ED-4701
2
-
-
times
Weight
-
8.5
-
-
g
(Note 9)
Heat-sink flatness
-50
100
μm
Note 8: Plain washers (ISO 7089~7094) are recommended.
Note 9: Measurement point of heat sink flatness
4.6mm
Measurement position
-
+
17.5mm
Heat sink side
-
+
Heat sink side
RECOMMENDED OPERATION CONDITIONS
Limits
Symbol
Parameter
Condition
Unit
Min.
Typ.
300
15.0
15.0
-
Max.
VCC
Supply voltage
Applied between P-NU, NV, NW
Applied between VP1-VNC, VN1-VNC
0
13.5
13.0
-1
400
16.5
18.5
+1
V
V
VD
Control supply voltage
Control supply voltage
Control supply variation
Arm shoot-through blocking time
PWM input frequency
VDB
Applied between VUFB-U, VVFB-V, VWFB-W
V
ΔVD, ΔVDB
tdead
V/μs
μs
For each input signal
1.0
-
-
-
fPWM
TC ≤ 100°C, Tj ≤ 125°C
-
20
kHz
VCC = 300V, VD = 15V, P.F = 0.8,
Sinusoidal PWM
fPWM= 5kHz
-
-
-
-
10.0
6.0
IO
Allowable r.m.s. current
Arms
fPWM= 15kHz
(Note 11)
TC ≤ 100°C, Tj ≤ 125°C
(Note10)
PWIN(on)
PWIN(off)
VNC
0.7
0.7
-5.0
-20
-
-
-
-
-
Minimum input pulse width
μs
-
VNC variation
Between VNC-NU, NV, NW (including surge)
+5.0
+125
V
Tj
Junction temperature
°C
Note 10: Allowable r.m.s. current depends on the actual application conditions.
11: DIPIPM might not make response if the input signal pulse width is less than PWIN(on), PWIN(off).
Publication Date : October 2013
5