MT90220
Address (Hex):
Direct access
in number of cells)
Reset Value (Hex):
288, 28A, 28C, 28E
1 value for each IMA Group to use for start-up and adding/removing delay (value
04
Bit #
Type
Description
LSB of the Guardband/Delay value Bits 7:0.
7:0
R/W
Table 72 - RX Guardband/Delta Delay LSB Register
Address (Hex):
Direct access
287, 289, 28B, 28D
1 value for each IMA Group to use for start-up and adding/removing delay
(value in number of cells)
00
Reset Value (Hex):
Bit #
Type
Description
7:6
5:0
R/W
R/W
Unused. Read 0 after reset.
MSB of the Guardband/Delay value Bits 13:8.
Table 73 - RX Guardband/Delta Delay MSB Register
Address (Hex):
Direct access
Reset Value (Hex):
296, 298, 29A, 29C
1 register per IMA Group (value in number of cells)
00
Bit #
Type
Description
7:0
R/W
LSB of the Maximum Operational Delay value Bits 7:0.
Table 74 - RX Maximum Operational Delay LSB Register
Address (Hex):
Direct access
Reset Value (Hex):
295, 297, 299, 29B
1 reg. per IMA Group (value in number of cells)
00
Bit #
Type
Description
7:6
5:0
R/W
R/W
Unused. Read 0 after reset.
MSB of the Maximum Operational Delay value Bits 13:8.
Table 75 - RX Maximum Operational Delay MSB Register