P30-65nm SBC
13.0
Maximum Ratings and Operating Conditions
13.1
Absolute Maximum Ratings
Warning:
Stressing the device beyond the Absolute Maximum Ratings may cause permanent
damage. These are stress ratings only.
Table 19: Absolute Maximum Ratings
Parameter
Maximum Rating
Notes
Temperature under bias
Storage temperature
Voltage on any signal (except VCC, VPP and VCCQ)
VPP voltage
–40°C to +85°C
–65°C to +125°C
–0.5V to +4.1V
–0.2V to +10.0V
–0.2V to +2.5V
–0.2V to +4.1V
100mA
-
-
1
1,2,3
1
VCC voltage
VCCQ voltage
1
Output short circuit current
Notes:
4
1.
Voltages shown are specified with respect to V . Minimum DC voltage is –0.5V on input/output signals and –0.2V on
VCC, VCCQ, and VPP. During transitions, this level may undershoot to –2.0V for periods less than 20ns. Maximum DC
SS
voltage on VCC is VCC + 0.5V, which, during transitions, may overshoot to VCC + 2.0V for periods less than 20ns.
Maximum DC voltage on input/output signals and VCCQ is VCCQ + 0.5V, which, during transitions, may overshoot to
VCCQ + 2.0V for periods less than 20ns.
2.
3.
Maximum DC voltage on VPP may overshoot to +11.5V for periods less than 20ns.
Program/erase voltage is typically 1.7V – 2.0V. 9.0V can be applied for 80 hours maximum total, to any blocks for 1000
cycles maximum. 9.0V program/erase voltage may reduce block cycling capability.
Output shorted for no more than one second. No more than one output shorted at a time.
4.
13.2
Operating Conditions
Note:
Operation beyond the Operating Conditions is not recommended and extended
exposure beyond the Operating Conditions may affect device reliability.
Table 20: Operating Conditions
Symbol
Parameter
Min
Max
Unit
Notes
T
Operating Temperature
VCC Supply Voltage
–40
+85
2.0
3.6
3.6
3.6
9.5
80
°C
1
C
VCC
1.7
CMOS inputs
TTL inputs
1.7
-
VCCQ
I/O Supply Voltage
2.4
V
V
V
Voltage Supply (Logic Level)
PP
0.9
PPL
PPH
PPH
V
Buffered Enhanced Factory Programming V
8.5
PP
t
Maximum V Hours
PP
VPP = V
VPP = V
VPP = V
VPP = V
-
Hours
Cycles
PPH
PPL
PPH
PPH
2
Main and Parameter Blocks
Main Blocks
100,000
-
Block
Erase
Cycles
-
-
1000
2500
Parameter Blocks
Notes:
1.
2.
T = Case Temperature.
C
In typical operation VPP program voltage is V
.
PPL
Datasheet
45
Apr 2010
OrderNumber:208033-02