EBDW020A0B Barracuda™ Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
Summary of Supported PMBus Commands
This section outlines the PMBus command support for the EBDW020A0B bus converters. Each supported command is outlined in
order of increasing command codes with a quick reference table of all supported commands included at the end of the section.
Each command will have the following basic information.
Command Name [Code]
Command support
Data format
Factory default
Additional information may be provided in tabular form or other format, if necessary.
OPERATION [0x01]
Command support: On/Off Immediate and Margins (Act on Fault). Soft off with sequencing not supported and Margins (Ignore
Fault) not supported. Therefore bits 6, 3, 2, 1 and 0 set as read only at factory defaults.
Format
8 bit unsigned (bit field)
Bit Position
Access
7
r/w
6
r
5
r/w
4
r/w
3
r
2
r
1
r
0
r
Function
Default Value
ON/OFF
Bits[5:4]
Bits[3:2]
N/A
1
0
0
0
1
0
0
0
ON_OFF_CONFIG [0x02]
Command support: Bit 1 polarity will be set based upon module code [0=Negative on/off logic, 1=positive on/off logic to allow
customer system to know hardware on/off logic
Format
8 bit unsigned (bit field)
Bit Position
Access
7
r
6
r
5
r
4
r
3
r
2
r/w
1
r
0
r
Function
(reserved)
Bit 4 pu
Bit 3 cmd
Bit 2 cpr
Bit 1 pol
module
code
Bit 0 cpa
Default Value
0
0
0
1
1
1
1
CLEAR_FAULTS [0x03]
Command support: All functionality
STORE_DEFAULT_ALL[0x11]
Command support: All functionality – Stores operating parameters to EEprom memory.
RESTORE_DEFAULT_ALL[0x12]
Command support: All functionality – Restores operating parameters from EEprom memory.
VOUT_MODE[0x20]
Command support: Supported. Factory default: 0x14 – indicates linear mode with exp = -12
Format
8 bit unsigned (bit field)
Bit Position
Access
7
r
6
r
5
r
4
r
3
r
2
r
1
r
0
r
Function
Default Value
Mode (linear)
0
2’s complement exponent
1
0
0
1
0
0
0
VOUT_COMMAND [0x21]
Data format: 16 bit unsigned mantissa (implied exponent per VOUT_MODE)
Factory default: 12.000V ( 12.00 / 2-12 → 49,152 = 0xC000 )
Range limits (max/min): 13.200V/5.000V
Units: volt
Command support: Supported
VOUT_CAL_OFFSET [0x23]
Range limits (max/min): +0.25/-0.25
Units: volt
Command support: read/write support, lockout per MFR_DEVICE_TYPE, functionality implemented