 浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第14页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第15页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第16页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第17页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第19页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第20页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第21页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第22页  
Data Sheet  
GE  
EBDW020A0B Barracuda™ Series; DC-DC Converter Power Modules  
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output  
bits are used for two’s complement representation of the  
mantissa, with the 11th bit fixed at zero since only positive  
numbers are valid. The data associated with TON_RISE and  
TON_DELAY can be stored to non-volatile memory using the  
STORE_DEFAULT_ALL command.  
data in the linear format. The upper five bits [7:3] of the high  
data byte form the two’s complement representation of the  
exponent, which is fixed at –3 (decimal). The remaining 11  
bits are used for two’s complement representation of the  
mantissa, with the 11th bit fixed at zero since only positive  
numbers are valid.  
Output Voltage Adjustment Using the PMBus  
During module manufacture, offset and gain correction  
values are written into the non-volatile memory of the  
module to null errors in the tolerance and A/D conversion of  
Vin. The command MFR_VIN_READ_CAL_OFFSET can be used  
to read the offset - two bytes consisting of a five-bit  
exponent (fixed at -3) and a 11-bit mantissa in two’s  
complement format. The resolution is 120mV. The command  
MFR_VIN_READ_CAL_GAIN can be used to read the gain  
correction - two bytes consisting of a unsigned 16 bit  
number. The resolution of this correction factor 0.000122.  
The corrected input voltage reading is then given by:  
The EBDW020A0B module output voltage set point is  
adjusted using the VOUT_COMMAND. The output voltage  
setting uses the Linear data format, with the 16 bits of the  
VOUT_COMMAND formatted as an unsigned mantissa, and a  
fixed exponent of -12 (decimal) (read from VOUT_MODE).  
VOUT = Mantissa x 2-12  
The range limits for VOUT_COMMAND are 5.00V to 13.20V,  
and the resolution is 0.244mV.  
The data associated with VOUT_COMMAND can be stored to  
non-volatile memory using the STORE_DEFAULT_ALL  
command.  
V (Read)  
IN  
[V (A/D)(MFR_VIN_READ_CAL_GAIN/8192)]  
IN  
Output Voltage Margining Using the PMBus  
MFR_VIN_READ_CAL_OFFSET  
The EBDW020A0B module can also have its output voltage  
margined via PMBus commands. The command  
Measuring Output Current Using the PMBus  
VOUT_MARGIN_HIGH sets the margin high voltage, while the  
command VOUT_MARGIN_LOW sets the margin low voltage.  
Both the VOUT_MARGIN_HIGH and VOUT_MARGIN_LOW  
commands use the “Linear” mode with the exponent fixed at  
–12 (decimal). The data associated with VOUT_MARGIN_HIGH  
and VOUT_MARGIN_LOW can be stored to non-volatile  
memory using the STORE_DEFAULT_ALL command.  
The module measures output current by using the output  
filter inductor winding resistance as a current sense element.  
The module can provide output current information using the  
READ_IOUT command. The command returns two bytes of  
data in the linear format. The upper five bits [7:3] of the high  
data byte form the two’s complement representation of the  
exponent, which is fixed at –4 (decimal). The remaining 11  
bits are used for two’s complement representation of the  
mantissa, with the 11th bit fixed at zero since only positive  
numbers are valid.  
The module is commanded to go to the margined high or low  
voltages using the OPERATION command. Bits [5:2] are used  
to enable margining as follows:  
00XX  
0110  
1010  
:
:
:
Margin Off  
Margin Low (Act on Fault)  
Margin High (Act on Fault)  
During module manufacture, offset and gain correction  
values are written into the non-volatile memory of the  
module to null errors in the tolerance and A/D conversion of  
IOUT. The command MFR_IOUT_CAL_OFFSET can be used to  
read the offset - two bytes consisting of a five-bit exponent  
(fixed at -4) and a 11-bit mantissa in two’s complement  
format. The resolution is 0.19A. The command  
MFR_IOUT_CAL_GAIN can be used to read the gain  
correction - two bytes consisting of a unsigned 16 bit  
number. The resolution of this correction factor 0.000122.  
The READ_IOUT command provides module average output  
current information. This command only supports positive  
current sourced from the module. If the converter is sinking  
current a reading of 0 is provided.  
Measuring Output Voltage Using the PMBus  
The module can provide output voltage information using  
the READ_VOUT command. The command returns two bytes  
of data in the linear format, with the 16 bits of the  
READ_VOUT formatted as an unsigned mantissa, and a fixed  
exponent of -12 (decimal).  
During module manufacture, an offset correction value is  
written into the non-volatile memory of the module to null  
errors in the tolerance and A/D conversion of VOUT. The  
command MFR_VOUT_READ_CAL_OFFSET can be used to  
read the offset - two bytes consisting of a signed 16-bit  
mantissa in two’s complement format, using a fixed  
exponent of -12 (decimal). The resolution is 0.244mV. The  
corrected Output voltage reading is then given by:  
IOUT (Read)  
[IOUT (A/ D)(MFR _ IOUT _CAL _GAIN /8192)]  
MFR _ IOUT _ CAL _ OFFSET  
Note that the current reading provided by the module is  
corrected for temperature.  
VOUT(Read) [VOUT(A/ D)   
MFR_VOUT_ READ_CAL_OFFSET  
Measuring Input Voltage Using the PMBus  
The module can provide input voltage information using the  
READ_VIN command. The command returns two bytes of  
April 15, 2013  
©2012 General Electric Company. All rights reserved.  
Page 18  