 浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第19页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第20页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第21页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第22页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第24页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第25页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第26页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第27页  
Data Sheet  
GE  
EBDW020A0B Barracuda™ Series; DC-DC Converter Power Modules  
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output  
OT_WARN_LIMIT [0x51]  
Range limits (max/min): 125/25  
Units: degrees C.  
Command support: All functionality  
Note: Range cross-check – value must be less than OT_FAULT_LIMIT value.  
VIN_OV_FAULT_LIMIT [0x55]  
Range limits (max/min): 90/48  
Units: volt  
Command support: All functionality  
VIN_OV_FAULT_RESPONSE [0x56]  
Command support:  
Response settings (bits RSP0:1) – only settings of 11 (The device’s output is disabled while the fault is present.) is supported..  
Retry settings (bits RS0:2) – only settings of 000 (unit does not attempt to restart on fault.  
Delay time setting (bits 0-2) – only DT0:2 = 0 (no delay) supported.  
Default Settings: The default settings for the VIN_OV_FAULT_RESPONSE command are;  
The unit shuts down in response to a VIN over voltage condition.  
The unit will continuously prepares to restart (normal startup) while the VIN over voltage condition is present until it  
is commanded off, bias power is removed, the VIN over voltage condition is removed, or another fault condition  
causes the unit to shutdown.  
The shutdown delay is set to 0 delay cycles.  
Format  
8 bit unsigned (bit field)  
Bit Position  
Access  
Function  
7
6
5
4
3
2
1
0
r
RSP[1]  
1
r
RSP[0]  
1
r
RS[2]  
0
r
RS[1]  
0
r
RS[0]  
0
r
DT[2]  
0
r
DT[1]  
0
r
DT[0]  
0
Default Value  
POWER_GOOD_ON [0x5E]  
Range limits (max/min): 13.2/5.0  
Units: volt  
Command support: full support  
Note: Range cross-check – value must be greater than POWER_GOOD_OFF value by 1.6V.  
POWER_GOOD_OFF [0x5F]  
Range limits (max/min): 13.2/5.0  
Units: volt  
Command support: full support  
Note: Range cross-check – value must be less than POWER_GOOD_ON value by 1.6V.  
TON_DELAY [0x60]  
Range limits (max/min): 500/10  
Units: milliseconds  
Command support: full support  
TON_RISE [0x61]  
Range limits (max/min): 500/15  
Units: milliseconds  
Command support: full support  