 浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第18页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第19页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第20页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第21页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第23页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第24页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第25页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第26页  
Data Sheet  
GE  
EBDW020A0B Barracuda™ Series; DC-DC Converter Power Modules  
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output  
IOUT_OC_FAULT_LIMIT [0x46]  
Range limits (max/min): 41.5/20  
Units: amp  
Command support: All functionality  
Note: Range cross-check – value must be greater than IOUT_OC_WARN_LIMIT value.  
IOUT_OC_FAULT_RESPONSE [0x47]  
Command support:  
Response settings (bits RSP0:1) – only settings of 11, unit shuts down and responds according to the retry settings  
below, is supported.  
Retry settings (bits RS0:2) – only settings of 000 (unit does not attempt to restart on fault) and 111 unit continuously  
restarts (normal startup) while fault is present until commanded off, bias power is removed or another fault  
condition causes the unit to shutdown.  
Delay time setting (bits 0-2) – only DT0:2 = 0 (no delay) supported.  
Default Settings: The default settings for the IOUT_OC_FAULT_RESPONSE command are;  
The unit shuts down in response to an IOUT over current condition.  
The unit will continuously restart (normal startup) while the IOUT over current condition is present until it is  
commanded off, bias power is removed or another fault condition causes the unit to shutdown.  
The shutdown delay is set to 0 delay cycles.  
Format  
8 bit unsigned (bit field)  
Bit Position  
Access  
Function  
7
6
5
r/w  
RS[2]  
1
4
r/w  
RS[1]  
1
3
r/w  
RS[0]  
1
2
1
0
r
RSP[1]  
1
r
RSP[0]  
1
r
DT[2]  
0
r
DT[1]  
0
r
DT[0]  
0
Default Value  
IOUT_OC_WARN_LIMIT [0x4A]  
Range limits (max/min): 30.3/7.6  
Units: amp  
Command support: read/write support, functionality complete  
Note: Range cross-check – value must be less than IOUT_OC_FAULT_LIMIT value.  
OT_FAULT_LIMIT [0x4F]  
Range limits (max/min): 140/25  
Units: degrees C.  
Command support: All functionality  
Note: Range cross-check – value must be greater than OT_WARN_LIMIT value.  
OT_FAULT_RESPONSE [0x50]  
Command support:  
Response settings (bits RSP0:1) – only setting of 10, unit shuts down and responds according to the retry settings  
below.  
Retry settings (bits RS0:2) – only settings of 000 (unit does not attempt to restart on fault) and 111 unit continuously  
restarts (normal startup) while fault is present until commanded off, bias power is removed or another fault  
condition causes the unit to shutdown.  
Delay time setting (bits 0-2) – only DT0:2 = 0 (no delay) supported.  
Default Settings: The default settings for the OT_FAULT_RESPONSE command are;  
The unit shuts down in response to an over-temperature condition.  
The unit will continuously restart (normal startup) while the over-temperature condition is present until it is  
commanded off, bias power is removed or another fault condition causes the unit to shutdown.  
The shutdown delay is set to 0 delay cycles.  
Format  
8 bit unsigned (bit field)  
Bit Position  
Access  
Function  
7
6
5
r/w  
RS[2]  
1
4
r/w  
RS[1]  
1
3
r/w  
RS[0]  
1
2
1
0
r
RSP[1]  
1
r
RSP[0]  
0
r
DT[2]  
0
r
DT[1]  
0
r
DT[0]  
0
Default Value  
April 15, 2013  
©2012 General Electric Company. All rights reserved.  
Page 22  